11
START UP AND OPERATION
PRO 36 AUTO
thickness does not provide sufficient holding force. In
such
case,
the
adhesion
force
will be
only
about
25 %
of
the
force
attained
on a standard 22 mm (0.87’’) flat plate.
If the motor does not continue operation after the green MOTOR button is
pushed and released, it means that the control circuit is operating properly and
preventing further drilling because of too low adhesion force.
3.4. Preparing
Before beginning, clean steel parts, especially the Weldon shank, from grease used
to preserve the machine for storage and transport.
Mount the annular cutter into the arbor in the manner described before.
Position the machine on a flat ferromagnetic surface (some types of stainless
and acid-proof steel do not conduct magnetic flux) with the thickness of at least 6 mm
(0.23’’). The workpiece must be clean, without rust or paint that decrease the holding
force of the electromagnetic base.
Then,
connect
the
drilling
machine
to
the
power
outlet
and enable the holding force
of the electromagnetic base by toggling the MAGNET switch to position ‘I’.
Protect the machine using the safety strap to prevent possible injury if the
machine loses magnetic adhesion in case of a power loss. In order to do this, either
mount the strap through the opening in the machine body (Figure 7a, 7b) or catch
the strap on the carrying handle when working in horizontal position (Figure 7c). The
strap must be tight, not twisted, and must be replaced every single time the machine
hangs on
the strap as a result of coming loose
from steel. Never insert the strap into
the buckle from the front (Figure 7d).
PRO 36 AUTO Operator’s Manual
a)
b)
c)
d)
INCORRECT
CORRECT
11
PRO 36 AUTO
thickness does not provide sufficient holding force. In
such
case,
the
adhesion
force
will be
only
about
25 %
of
the
force
attained
on a standard 22 mm (0.87’’) flat plate.
If the motor does not continue operation after the green MOTOR button is
pushed and released, it means that the control circuit is operating properly and
preventing further drilling because of too low adhesion force.
3.4. Preparing
Before beginning, clean steel parts, especially the Weldon shank, from grease used
to preserve the machine for storage and transport.
Mount the annular cutter into the arbor in the manner described before.
Position the machine on a flat ferromagnetic surface (some types of stainless
and acid-proof steel do not conduct magnetic flux) with the thickness of at least 6 mm
(0.23’’). The workpiece must be clean, without rust or paint that decrease the holding
force of the electromagnetic base.
Then,
connect
the
drilling
machine
to
the
power
outlet
and enable the holding force
of the electromagnetic base by toggling the MAGNET switch to position ‘I’.
Protect the machine using the safety strap to prevent possible injury if the
machine loses magnetic adhesion in case of a power loss. In order to do this, either
mount the strap through the opening in the machine body (Figure 7a, 7b) or catch
the strap on the carrying handle when working in horizontal position (Figure 7c). The
strap must be tight, not twisted, and must be replaced every single time the machine
hangs on
the strap as a result of coming loose
from steel. Never insert the strap into
the buckle from the front (Figure 7d).
PRO 36 AUTO Operator’s Manual
a)
b)
c)
d)
INCORRECT
CORRECT
11
3.4. Preparing
Before beginning, clean steel parts, especially the Weldon shank, from grease used to
preserve the machine for storage and transport.
Mount the annular cutter into the arbor in the manner described in (3.1).
Position the machine on a flat ferromagnetic surface (some types of stainless and
acid-proof steel do not conduct magnetic flux) with the thickness of at least 6 mm (0.23’’).
The workpiece must be clean, without rust or paint that decrease the holding force of the
electromagnetic base.
Then, connect the drilling machine to the power outlet and enable the holding force of
the electromagnetic base by toggling the MAGNET switch to position ‘I’ (on).
Protect the machine using the safety strap to prevent possible injury if the machine
loses magnetic adhesion in case of a power loss. In order to do this, either mount the strap
through the opening in the machine body (Figure 7a, 7b) or catch the strap on the carrying
handle when working in horizontal position (Figure 7c). The strap must be tight, not twisted,
and must be replaced every single time the machine hangs on the strap as a result of
coming loose from steel. Never insert the strap into the buckle from the front (Figure 7d).
Figure 7. Securing the drilling machine using the safety strap
Vertical drilling
Horizontal drilling
Inverted drilling
Содержание Pro 35 Auto