Hobart CLF 26 Скачать руководство пользователя страница 7

 

INSTALLATION 

Page 5 

 

INSTALLATION 

 

T

HE MANUFACTURER ACCEPTS NO LIABILITY FOR ANY DAMAGE TO OBJECTS OR 

PERSONAL INJURY ARISING FROM INSTALLATIONS WHICH FAIL TO COMPLY WITH 

THE INSTRUCTIONS PROVIDED

 

1. Glossary 

 In this document, the terms Main switchwater supply stop cock and Drain line are defined 

as follows: 
 

M

AIN 

S

WITCH

 

Must be of the type which  disconnects all conductors of the supply circuit including the 
neutral
, with a distance between the open contacts of at least 3 mm, incorporating a thermal 
magnetic circuit breaker or fuses,  to be sized or calibrated in accordance with the power rating 
indicated on the appliance data plate. 
The main switch must be located near to the installation and must serve only one machine. 
 

WATER SUPPLY STOP COCK: 

 

This must be a slide, ball or gate stop valve capable of rapid and complete shut-off of the water 
supply
, of sufficient dimensions to ensure the flow rate and pressure indicated on the machine data 
plate. 
If the water supply pressure exceeds the prescribed maximum, a pressure regulator must be installed 
upstream of the machine. If the supply pressure is below the prescribed minimum, a pressure 
booster pump must be installed upstream of the machine. 
If the temperature of the incoming water is below the recommended minimum, additional steps 
must be taken to obtain good washing results (see chapter “USE  AND MAINTENANCE”) 
The stop cock must be installed on the water supply pipe near to and immediately upstream of the 
appliance

 

D

RAIN LINE

 

 

Must comprise an open trap of sufficient dimensions to discharge at least double the required 
supply flow. 
It must be installed within reach of the discharge pipe supplied with the machine without this being 
subject to tension, kinking or joints

 

Содержание CLF 26

Страница 1: ...Manuals and Instructions Brought to your courtesy of wechillit com Ltd Sales Team 01743 284918...

Страница 2: ...CLF 26 Installation Operation...

Страница 3: ...________________________________________________ 6 4 Connections_____________________________________________________________________ 6 5 Dispenser settings ___________________________________________...

Страница 4: ...and contains instructions covering the entire service life of the appliance installation reserved for qualified technicians use and maintenance addressed to the user II Technical documentation In add...

Страница 5: ...he protective panels unless carried out by qualified and authorized personnel in compliance with the manufacturer s instructions such persons must always disconnect the machine from the electrical pow...

Страница 6: ...ion data For correct installation follow all the instructions in the section Installation All the data necessary for correct installation of the appliance can be found on the data plate affixed to the...

Страница 7: ...lide ball or gate stop valve capable of rapid and complete shut off of the water supply of sufficient dimensions to ensure the flow rate and pressure indicated on the machine data plate If the water s...

Страница 8: ...ion The appliance must be leveled using the four adjustable feet so that it is perfectly stable any other type of installation must be agreed and approved by the manufacturer 4 Connections I Electrica...

Страница 9: ...rities or air pockets which could soil or damage the machine Connect the filling solenoid valve to the stop cock with a flexible pipe III Drain line A suitable Drain line must be provided see Glossary...

Страница 10: ...uired dosage open the adjuster screw until this quantity is obtained Electric dispenser DB 2 One full turn of the adjuster screw is approximately equivalent to 0 06 grams of product per dispenser puls...

Страница 11: ...e dispenser setting should carried out by a qualified technician Refer to the dosage indicated by the detergent manufacturer taking into account characteristics of the water in your area the type of i...

Страница 12: ...results obtained after a number of real wash cycles turn the potentiometer clockwise to increase the dosage and counter clockwise to decrease it 6 Operator training The installer is required to provi...

Страница 13: ...always disconnect the appliance from the electrical power supply at the external main switch and shut off the water supply at the supply tap Do not clean the appliance using pressurized water jets as...

Страница 14: ...the machine I Detergents The type and quantity of detergent used determine the washing results obtained from the appliance and the length of its service life Detergents are not supplied with the appli...

Страница 15: ...witch 3 Set the machine to wash mode by pressing switch 1 The wash chamber will automatically start to fill For appliances without detergent dispensers only Add detergent in the region of the pump suc...

Страница 16: ...items are to be used immediately and require a cold rinse beer glasses ice cream dishes press button 5 for 10 20 seconds to perform a further rinse cycle using fresh water drawn directly from the main...

Страница 17: ...Remove the overflow plug III Press the drain pump button 6 to drain releasing it when the chamber is empty 6 Before the daily shutdown Remove the overflow plug and empty the machine as described in t...

Страница 18: ...properly in their respective mountings Refit all the filters III Major maintenance Once a year or whenever limescale deposits are noted in the machine call a specialist technician to Remove limescale...

Страница 19: ...ee instructions Grease or starch not completely removed Too little detergent Increase dosage as per instructions in relative section of this manual Wrong type of detergent Choose a more effective prod...

Страница 20: ...two or three consecutive regeneration cycles adding salt each time Descale the machine Water supply filter clogged Clean or if necessary replace with a higher capacity filter IV Miscellaneous problem...

Страница 21: ...c doseur produit de lavage Con dosatore detergente E With break tank Mit break tank Avec break tank Con break tank G With DB2 Mit DB2 Avec DB2 Con DB2 With drain pump Mit umwaelzpumpe Avec pompe de vi...

Страница 22: ...curity relay T rsicherheit Relais Relais securite de porte Rel sicurezza porta Rel de de segurancia puerta Rel de seguran a porta K11 Heating control relay ReIais Versorgung Heizk rper evt Sch tz Rela...

Страница 23: ...2 5mm 3x1 5mm 3x4mm Det pipe length N A 1 50M 1 50M 1 50M R aid pipe length 1 50M 1 50M 1 50M 1 50M 1 50M Programme times secs 150 60 120 180 60 120 180 150 60 180 Wat consumption cycle 2 6L 3 3L 3L 2...

Страница 24: ...thout notice Ce catalogue n est pas contractuel HOBART se r serve le droit et sans pr avis d apporter toutes modifications ou am liorations ses mat riels HOBART beh lt sich das Recht vor an allen Prod...

Отзывы: