USE AND MAINTENANCE
Page
18
III Water
softener
(Optional)
P
ROBLEM
R
EMEDY
Excess salt in rinse water.
Salt left in container after regeneration. Only fill container
immediately before starting the regeneration cycle with the
quantity of salt indicated in the operating instructions.
Wrong size salt grains. Use salt with a grain size of 1 - 2 mm
Excessive salinity after resin regeneration.
External water softener. Rinse the resin at the end of the
regeneration cycle, draining the water container in the water
softener.
Built-in water softener. Salt container cap not fully tightened.
Open container, remove salt using hot water, replace cap and
screw on tightly..
Limescale deposits in machine
Regeneration not performed correctly at right time.
perform two or three consecutive regeneration cycles, adding
salt each time.
Descale the machine.
Water supply filter clogged. Clean or, if necessary, replace
with a higher capacity filter.
IV Miscellaneous
problems
P
ROBLEM
R
EMEDY
Tableware broken by impact during wash cycle.
Use suitable racks for the type of tableware and do not
overload.
Machine stops in middle of cycle.
Machine interconnected with other appliances. Provide
separate power supply for the machine with a switch or fuses
suitably rated for the current indicated on the data plate.
If the problem recurs, have the system checked by a qualified
electrician.
Machine fails to start after a period of inactivity.
Have a qualified technician turn the pump motor over using
the splines on the opposite end of the shaft to the pump
impeller.
The cycle does not stop when the door is opened.
Have a qualified technician repair the door safety switch and
check the magnetic contact and its circuit.