53 (124)
Limit
•
Name:
You can name the Frame Field to make it easier to identify.
•
Type:
Specify the number of bytes in the frame. Select Byte (1 byte) (Default), Word (2
bytes), Double word (4 bytes).
•
Endianess:
Select Big-endian (Default) or Little-endian.
•
Min value:
The lowest value of the limit range.
•
Max value:
The highest value of the limit range.
•
Base number system:
Select Decimal
Dec
(Default) or Hexadecimal
Hex
.
Data
•
Name:
You can name the Frame Field to make it easier to identify.
•
Fixed field*:
Select Yes, set here (Default) or No, set when used.
•
Length:
Enter a value between 1 (Default) and 512 bytes.
•
Min length:
Specify the minimum length that can be set when the template is used.
•
Max length:
Specify the maximum length that can be set when the template is used.
•
Default length:
Specify the default length that can be set when the template is used.
Variable data
•
Name:
You can name the Frame Field to make it easier to identify.
•
Fixed field*:
Select Yes, set here (Default) or No, set when used.
•
Minimum payload length:
Specify the minimum payload length that can be set when the
template is used.
•
Maximum payload length:
Specify the maximum payload length that can be set when the
template is used.
•
Default max payload length:
Specify the default payload length that can be set when the
template is used.
•
Data delimiter:
Specify how to detect/define the length of the variable data of the high
level network. Select Byte counter, End pattern or None (Default).
For information about End- and Length character, refer to
.
•
Subnet delimiter:
Specify how to detect/define the length of the variable data of the serial
subnetwork. Select Byte counter, End pattern or None (Default).
For information about End- and Length character, refer to
.
•
End pattern:
Specify the value defining the end of the payload, when a delimiter is set to
end pattern.
•
Fill padding:
Fill up unused data mapped to the high level network or the general area with
a field padding value.
To deactivate/activate Fill padding, click the
slide toggle
. When Fill padding is activated,
enter a Fill padding value between 0 and 255.
•
Base number system:
Select Decimal
Dec
(Default) or Hexadecimal
Hex
.
Checksum
•
Name:
You can name the Frame Field to make it easier to identify.
Anybus
®
Communicator
™
User Manual
SCM-1202-152 1.10 en-US