26 (124)
6.2
Setup New Configuration
Follow these steps to setup a new Communicator configuration.
1. Subnetwork configuration
On the
Communication
page:
a.
Select a serial protocol:
–
Modbus RTU
(default)
–
Custom Request/Response
–
Custom Produce/Consume
For information about the serial
protocol types, refer to
.
b.
Configure the basic settings Physical
standard, Baud rate, Data bits, Parity
and Stop bits.
2. Create Transaction Templates
This step applies when the serial protocol
Custom Request/Response
or
Custom
Produce/Consume
is selected.
On the
Transaction templates
page: Add
a transaction template for each way
information can be requested/received or
produced/consumed.
Repeat until you have added and
configured all your transaction templates.
3. Add Nodes and Transactions
On the
Nodes & transactions
page:
a.
Add a node and configure the Node
settings.
b.
Add transactions to request/receive
data or produce/consume data and
configure the transaction settings.
Repeat until you have added and
configured all your nodes.
Anybus
®
Communicator
™
User Manual
SCM-1202-152 1.10 en-US