MAINTENANCE
7-55
d
CAUTION: Wear goggles or safety glasses when using
compressed air [less than 0.2 MPa (2 kgf/cm
2
)].
6. Remove adapter (8) from adapter (9) and clean filter (11)
by blowing compressed air or cleaning solution from the
oil flow outlet side.
7. Install the cleaned filter with washer (10) and adapters (7,
8, 9).
f
NOTE: If washer (10) and filter (11) are removed, carefully
install the washer evenly in adapter (9), otherwise, adapter (8)
cannot be fully tightened, causing leakage.
8. After cleaning the filter, bleed air from the hydraulic
pump and check the oil level in the hydraulic oil tank.
(Refer to the descriptions for "Bleed air from the
hydraulic system" in item
.)
If the machine is operated without bleeding the air
mixed in the hydraulic circuit, damage to the hydraulic
pump may result.
f
NOTE: Clean the element at the regular intervals to maintain
clean hydraulic oil and extend the service life of the hydraulic
components.
90Z7B-7-51-1
90Z7B-7-50-3
7
7
8
8
Air Flow
Oil Flow
9
9
10
11
Содержание ZW 310-6
Страница 4: ......
Страница 10: ...CONTENTS MEMO ...
Страница 14: ...INTENDED USE 2 MEMO ...
Страница 57: ...SAFETY SIGNS S 43 ZW310 6 SS 3777 2 ...
Страница 59: ...SAFETY SIGNS S 45 ZW330 6 92Z7B S 40EU ...
Страница 203: ...OPERATOR S STATION 1 137 Coat Hook Use to hang your coat hat etc MNEC 01 518 MNEC 01 053 ZW310 6 ZW330 6 ...
Страница 246: ...BREAK IN 2 2 MEMO ...
Страница 280: ...DRIVING MACHINE 4 20 MEMO ...
Страница 460: ...MAINTENANCE 7 146 MEMO ...
Страница 464: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 4 MEMO ...
Страница 468: ...STORAGE 10 4 MEMO ...
Страница 474: ...TROUBLESHOOTING 11 6 MEMO ...
Страница 498: ...INDEX 14 6 MEMO ...
Страница 502: ...CONFORMITY MEMO ...
Страница 506: ......