MAINTENANCE
7-38
Table 1. Hoses
Interval (hours)
Check Points
Abnormalities
Remedies
Daily
Hose covers
Hose ends
Fittings
Leak (1)
Leak (2)
Leak (3)
Replace
Replace
Retighten or replace
hose or O-ring
Every 250
hours
Hose covers
Hose ends
Hose covers
Hose covers
Hose
Hose
Hose ends and
fittings
Crack (4)
Crack (5)
Exposed reinforcement (6)
Blister (7)
Bend (8)
Collapse (9)
Deformation or
corrosion (10)
Replace
Replace
Replace
Replace
Replace
Replace
(Use proper bend
radius)
Replace
NOTE: Refer to the illustrations in Fig.1 for each check point location or for a description of the
abnormality. Use genuine Hitachi parts.
Fig. 1
M137-07-008
3
2
3
2
1
M115-07-145
3
2
3
2
1
M115-07-146
5
4
M115-07-147
6
7
M115-07-148
8
M115-07-149
9
10
Содержание ZAXIS 120-3 class
Страница 1: ......
Страница 3: ......
Страница 5: ......
Страница 49: ...SAFETY SIGNS Europe Asia Middle and Near East Model Only S 38 MEMO ...
Страница 131: ...BREAK IN 2 MEMO ...
Страница 191: ...TRANSPORTING 6 MEMO ...
Страница 290: ...HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT 8 HYDRAULIC CIRCUIT M1V1 08 001 ...
Страница 292: ...8 ELECTRICAL DIAGRAM ...
Страница 293: ...HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT 8 MEMO ...
Страница 295: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 MEMO ...
Страница 351: ...SPECIFICATIONS 12 42 MEMO ...
Страница 455: ...OPTIONAL ATTACHMENTS AND DEVICES 13 104 MEMO ...
Страница 460: ...INDEX 14 Working Ranges ZX280LC 3 280LCN 3 2 piece Boom 13 41 Working Ranges ZX350LC 3 350LCN 3 2 piece Boom 13 44 ...
Страница 461: ...INDEX 14 MEMO ...