MAINTENANCE
7-32
12. Remove drain plug (3). Allow oil to drain.
13. Remove suction filter and rod assembly (4).
14. Clean the filter and tank interior. If the filter is to be re-
placed, install new filter on the rod as shown. Tighten nut
to 15 to 20 N•m (1.5 to 2.0 kgf•m, 11.0 to 14.5 lbf•ft).
Model
A
ZX120-3 Class
732 mm (28.8 in)
ZX180-3, 200-3, 270-3, 330-3
Class
869 mm (34.2 in)
15. Install filter and rod assembly (4). Make sure the filter is
positioned correctly on the outlet.
16. Replace the hydraulic tank oil filter. (See “Maintenance
Every 500 Hours” Section)
17. Clean, install and tighten drain plug (3).
18. Add oil until it is between the marks on the oil level
gauge.
19. Install cover (2). Make sure filter and rod assembly (4) are
in correct positions. Tighten the bolts to 50 N•m (5 kgf•m,
36 lbf•ft).
20. Be sure to bleed air form the system following the proce-
dures shown next page.
M1U1-07-047
3
M157-07-062
2
4
M107-07-070
4
A
20 mm (0.79 in)
Содержание ZAXIS 120-3 class
Страница 1: ......
Страница 3: ......
Страница 5: ......
Страница 49: ...SAFETY SIGNS Europe Asia Middle and Near East Model Only S 38 MEMO ...
Страница 131: ...BREAK IN 2 MEMO ...
Страница 191: ...TRANSPORTING 6 MEMO ...
Страница 290: ...HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT 8 HYDRAULIC CIRCUIT M1V1 08 001 ...
Страница 292: ...8 ELECTRICAL DIAGRAM ...
Страница 293: ...HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT 8 MEMO ...
Страница 295: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 MEMO ...
Страница 351: ...SPECIFICATIONS 12 42 MEMO ...
Страница 455: ...OPTIONAL ATTACHMENTS AND DEVICES 13 104 MEMO ...
Страница 460: ...INDEX 14 Working Ranges ZX280LC 3 280LCN 3 2 piece Boom 13 41 Working Ranges ZX350LC 3 350LCN 3 2 piece Boom 13 44 ...
Страница 461: ...INDEX 14 MEMO ...