OEM MANUAL:K6602594
6 SENSE DATA
Revision: 1 / Date: 2003.03.06
Page: 262 / 273
1
17 06
Recovered Data
without ECC - Data
Auto-Reallocated
An error has been recovered by retries
(without ECC) and a sector has been
reallocated. Auto-Reallocation process was
performed.
1
17 07
Recovered Data
without ECC -
Recommend
Reassignment
The error has been recovered without ECC
correction. A reassignment is
recommended.
1
17 09
Recovered Data
without ECC-
Data Rewritten
The error has been recovered without ECC
correction and data rewritten.
1
17 86
Recovered Data
without ECC - Data
Auto-Reallocated,
Relocation
Threshold-Over
Data error has been recovered by ECC
correction and a sector has been reallocated.
Auto-Reallocation process was performed
but a relocation count was over its threshold
value.
1
18 00
Recovered Data
with Error
Correction Applied
Data error has been recovered by ECC
correction. (without retries)
1
18 01
Recovered Data
with Error
Correction &
Retries Applied
Data error has been recovered by ECC
correction and retries.
1
18 02
Recovered Data -
Data Auto-
Reallocated
Data error has been recovered by ECC
correction (retries may or may not be done)
and a sector has been reallocated. Auto-
Reallocation process was performed.
1
18 05
Recovered Data-
Recommend
Reassignment
Data error has been recovered by ECC
correction. A reassignment is
recommended.
1
18 07
Recovered Data
with ECC-Data
Rewritten
Data error has been recovered by ECC
correction and data rewritten.
1
18 82
Recovered Data -
Data Auto-
Reallocated,
Relocation
Threshold-Over
Data error has been recovered by ECC
correction and a sector has been reallocated.
Auto-Reallocation process was performed
but a relocation count was over its threshold
value.
1 or 3
19 00
Defect List error
Error exists in defect list.
1 or 3
19 01
Defect List Error
Not Available
Defect list could not be used.
1 or 3
19 02
Defect List Error in
Primary List
An error occurred during an access to the
Primary (P) list