OEM MANUAL:K6602924
3 SCSI BUS
Revision: 1 / Date: 2003.03.06
Page: 35 / 273
3.2.2 MESSAGES
The Table 3.1 lists the message supported by the controller.
Table 3.1 Messages
Code
Description
Direction
Remarks
00
H
COMMAND COMPLETE
In
01
H
EXTENDED MESSAGE
In
Out
Refer to 3.2.3
02
H
SAVE DATA POINTER
In
03
H
RESTORE POINTERS
In
04
H
DISCONNECT
In
05
H
INITIATOR DETECTED
ERROR
Out
06
H
ABORT(or ABORT TASK SET)
Out
07
H
MESSAGE REJECT
In
Out
08
H
NO OPERATION
Out
09
H
MESSAGE PARITY ERROR
Out
0A
H
LINKED COMMAND
COMPLETE
In
0B
H
LINKED COMMAND
COMPLETE (WITH FLAG)
In
0C
H
BUS DEVICE RESET
(or TARGET RESET)
Out
0D
H
ABORT TAG(or ABORT TASK)
Out
0E
H
CLEAR QUEUE
Out
12
H
CONTINUE I/O PROCESS
Out
13
H
TARGET TRANSFER DISABLE
Out
20
H
SIMPLE QUEUE TAG
In
Out 2-byte message
21
H
HEAD OF QUEUE TAG
Out 2-byte message
22
H
ORDERED QUEUE TAG
Out 2-byte message
23
H
IGNORE WIDE RESIDUE
In
2-byte message
55
H
QAS REQUEST
In
80
H
- FF
H
IDENTIFY
In
Out
In
: Controller ( Target ) to Host ( Initiator )
Out
: Host ( Initiator ) to Controller ( Target )
Command Complete (00
H
)
This message is sent from the controller to the host computer to indicate that
the execution of a command is complete and that a valid status has been sent to
the host computer. After sending this message, the controller releases the BSY
signal and enters the Bus Free phase.