OEM MANUAL:K6602924
5 COMMAND DESCRIPTIONS
Revision: 1 / Date: 2003.03.06
Page: 211 / 273
5.16 READ DEFECT DATA(12) :(B7
H
)
Bit
Byte
7
6
5
4
3
2
1
0
0
Operation Code (B7
H
)
1
0
1
1
0
1
1
1
1
Reserved
P
G
Defect List Format
0
0
0
2
Reserved
0
0
0
0
0
0
0
0
3
Reserved
0
0
0
0
0
0
0
0
4
Reserved
0
0
0
0
0
0
0
0
5
Reserved
0
0
0
0
0
0
0
0
6
Allocation Length (MSB)
7
Allocation Length
8
Allocation Length
9
Allocation Length (LSB)
10
Reserved
0
0
0
0
0
0
0
0
11
Vendor Unique
Reserved
Flag
Link
0
0
0
0
0
0
The READ DEFECT DATA(12) command is the same as the READ DEFECT
DATA command except that the READ DEFECT DATA(12) command has 4-byte
length of Allocation Length and 8-byte length of Read Defect Header as follows.
Refer to item 5.15 READ DEFECT DATA command in detail.
READ DEFECT DATA(12) :(B7h)