OEM MANUAL:K6602924
2 PRODUCT SPECIFICATION OUTLINE
Revision: 1 / Date: 2003.03.06
Page:
28
/ 273
·However, if the error in the data field is correctable by ECC the controller
corrects the error using ECC, and terminates the recovery procedure (this is
applicable when EER=1).
(2) Retry Count
The host computer can select the retry count by specifying the counts to the retry
count field of the error recovery parameter.
Notes for Retry Count
·It is recommended to specify the retry count value at more than 128 times in
normal operation.
·The controller performs the internal retry before the execution of retries
specified by the host computer. If an error is correctable, the controller corrects
the error using ECC during the internal retry. When the error is recovered by the
internal retry, the controller may not report the recovered error to the host
computer even if the PER of MODE Parameter page 01
H
is set.
2.4
SUPPORTED SCSI COMMANDS
This SCSI controller supports the group 0,1,2 and 5 commands listed in Table 2.1
based on SCSI-2 command set and additionally some SCSI-3 command set.
Table 2.1 Commands Supported
Operation
Code
Group 0 Command Name
Reference
00
H
TEST UNIT READY
5.32
01
H
REZERO UNIT
5.26
03
H
REQUEST SENSE
5.23
04
H
FORMAT UNIT
5.1
07
H
REASSIGN BLOCKS
5.18
08
H
READ
5.11
0A
H
WRITE
5.34
0B
H
SEEK
5.27
12
H
INQUIRY
5.2
15
H
MODE SELECT
5.5
16
H
RESERVE
5.24
17
H
RELEASE
5.20
1A
H
MODE SENSE
5.7
1B
H
START/STOP UNIT
5.30
1C
H
RECEIVE DIAGNOSTIC RESULTS
5.19
1D
H
SEND DIAGNOSTIC
5.29
(cont
’
d)