OEM MANUAL:K6602924
5 COMMAND DESCRIPTIONS
Revision: 1 / Date: 2003.03.06
Page: 103 / 273
Table 5.28 Last n Error Events Page(Page Code = 7H) (cont’d)
7
Parameter Length (x)
8
(MSB)
•
Event Description
x+7
(LSB)
|
|
n-y+4
•
Error Event (Last)
n+3
(Length y)
The parameter code in an error-event record indicates the relative time at which
the error occurred. The higher the parameter code indicates the later an error
event occurred. The valid parameter codes supported by this controller are from
0000
H
to FFFF
H
.
When the drive reaches beyond the last supported parameter code (FFFF
H
) for an
error-event record, then a parameter code of (000
H
) is to be taken as wraparound
codes.
Temperature Page (Page Code = 0D
H
)
This clause defines the optional temperature log page(page code 0D
H
).
The temperature sensed in the device at the time the LOG SENSE command is
performed shall be returned in the parameter field defined by parameter code
0000
H.
Temperature equal to or less than zero Degrees Celsius shall be indicated by a
value of zero. If a valid temperature cannot be detected because of a sensor failure
or other condition, the value returned shall be FF
H.
The temperature should be reported with an accuracy of plus or minus three
Celsius Degrees while the device is operating at a steady state within the
environmental limits specified for the device.
A reference temperature for the device provided by the device using parameter
code 0001
H
.
The one byte binary value should reflect the maximum reported sensor
temperature in degrees Celsius at which the device is capable of operating
continuously without degrading the device
’
s operation or reliability beyond
manufacture accepted limit.
LOG SELECT:(4Ch)