– 105 –
YES
YES
NO
NO
Is switching power circuit normal?
Is 3A fuse normal?
Operate the outdoor unit according
to the "Operation of the outdoor unit
indepndently".
What condition does the self-
disgnosis lamp indicate?
Are cords for connecting terminal
board, reactor, diode, smoothing
capacitor, etc. connected correctly
Securely insert them if loosened or
disconnected.
Is power circuit of compressor
normal? Refer to "Power circuit" for
details.
Is DC 35V output at C and D termi-
nals? (DC 33V - 40V is output in the
normal state.)
LD301: Blinking 10 times.
Half voltage error
Replace defective parts.
If 3A fuse has been blown, Q1,
switching transformer, ZD3, etc.
may be defective.
LD301: Blinks 9 times.
Communications error
YES
Содержание RAC-25CNH11
Страница 35: ... 35 CIRCUIT DIAGRAM MODEL RAS 25CNH11 ...
Страница 36: ... 37 CIRCUIT DIAGRAM MODEL RAC 25CNH11 ...
Страница 104: ... 113 PARTS LIST AND DIAGRAM MODEL RAS 25CNH11 11 2 18 8 20 19 12 63 1 4 60 3 7 14 15 6 5 16 13 88 61 17 9 62 10 ...
Страница 106: ... 115 MODEL RAC 25CNH11 55 22 59 16 26 24 23 20 21 19 13 52 58 53 56 57 2 3 51 15 14 18 4 5 9 6 8 54 17 7 11 10 12 25 ...
Страница 108: ...RAS 25CNH11 RAC 25CNH11 PM NO 0164E Printed in Malaysia HITACHI ...