– 43 –
Cooling
Dehumidifying
Heating
Fan speed mode : AUTO
Fan speed mode : Lo
Fan speed mode : AUTO
Room temp.
Cooling
preset temp.
Thermostat
judgement
Compressor
Hi
Med
Lo
(Compressor is
forced-stopped
for 3 min.)
OFF
ON
ON
Start/Stop switch
Compressor
Lo
32"
42.66
37.66
32.66
27.66
Compressor
rotates at
maximum speed
during Hot dash
operation or when
recovered from
defrosting.
Other than on left
Super Hi
Hi
Med
Lo
Heat exchanger temp.
Heat exchanger temp.
KAFON
KAFOF
Overload
Lo
Operation mode
Auto
Hi
Med.
Lo
Basic mode of
the
temperature
control
Fan speed mode (Indoor unit)
Cooling
Dehumidifying
Heating
Auto
Changes to "Med" or "Lo" from "Hi"
according to the room
temperature.
1. Operation continues in "Hi"
mode until the thermostat turns
off for the 1st time. ("Super Hi" is
set during Cool dash operation
with the compressor rotating at
maximum speed.)
2. Operates in "Lo" mode when the
thermostat is OFF.
"Super Hi" mode operation is done
during Cool dash operation with
the compressor rotating at
maximum speed, and "Hi" mode
operation is done in other modes.
"Med" mode operation is done
regardless of the room temperature.
"Lo" mode operation is done
regardless of the room temperature.
Refer to page 45.
"Lo" mode and "Stop" mode are
repeated according to the
compressor operation.
Refer to page 49.
Operation mode is changed to one
of "Super lo", "Lo", "Med", "Hi",
"Super Hi" and "Stop" according to
the room temperature, time and
heat exchanger temperature.
When the heat exchanger
temperature becomes 18˚C or less
except for the preheating
operation mode, "Stop" is set.
(The operation recovers at 18.66˚C)
Operation mode is changed to one
of "Lo", "Med", "Hi", "Super Hi" and
"Stop" according to the room
temperature and time.
"Super Hi" operation is done when
the compressor rotates at
maximum or when recovering from
defrosting.
Operation mode is changed to one
of "Lo", "Med" and "Stop"
according to the room temperature
and time.
Operation mode is changed to one
of "Lo" and "Stop" according to
the room temperature and time.
The fan speed is controlled by the
heat exchanger temperature and
overload control is done as shown
below.
Refer to page 51 and 53.
The following operation mode is
set depending on the room
temperature when the operation is
started.
However, in the auto cooling
mode, the Cool rhythm
operation starts when the room
temperature becomes the
preset tempe 0.66˚C after
the Dash operation is
completed.
Note:
1. Refer to data in Page 41 Table 1 and 2 for each constant shown by capital letters in the diagram.
Note
(1)Mode is not changed after the
operation is started.
(2)The preset temperature can be
changed within
±
3˚C using the
room temp. control button " "
"V". For example, if the preset
temperature for cooling is
increased by +2˚C to change it
to 29˚C, the preset
temperature for heating is also
changed to 25˚C.
Also the operation mode
selected from the room
temperature at the start of
operation is judged based on
the changed value.
V
Содержание RAC-25CNH11
Страница 35: ... 35 CIRCUIT DIAGRAM MODEL RAS 25CNH11 ...
Страница 36: ... 37 CIRCUIT DIAGRAM MODEL RAC 25CNH11 ...
Страница 104: ... 113 PARTS LIST AND DIAGRAM MODEL RAS 25CNH11 11 2 18 8 20 19 12 63 1 4 60 3 7 14 15 6 5 16 13 88 61 17 9 62 10 ...
Страница 106: ... 115 MODEL RAC 25CNH11 55 22 59 16 26 24 23 20 21 19 13 52 58 53 56 57 2 3 51 15 14 18 4 5 9 6 8 54 17 7 11 10 12 25 ...
Страница 108: ...RAS 25CNH11 RAC 25CNH11 PM NO 0164E Printed in Malaysia HITACHI ...