Hitachi KP-FD30 Скачать руководство пользователя страница 7

 

16.White balance      Selectable in 3 modes 
 

ATW / AWC / MANUAL 

17.Text display 
 

24 alpha-numeric characters in one line 

18.Camera setting menu 
 

Mode selection, quality-of-image adjustment 

19.Remote control 
 

RS-232C level (MULTI Connector) 

20. Power supply 

DC +12V ± 10% 

21. Power 

 consumption 

Approx. 360mA 
(Including 60mA for auto-iris lens) 

22.Lens mount 
 

C/CS mount ( Frange-back adjustment ) 

23. Ambient 
              temperature

 

Operating

-10

+50

/30

80%RH  

(*3)

Storage

-20

+60

/20

90%RH 

(*3)

 Note : If operated continuously, be sure to use at less than   

+40 (104F) for long term stable performance. 

24. Vibration 
        endurance

68.65 m/s ( 10 to 200Hz, 30 minutes each on 
XYZ axes )

 

 (*4)

 

 

(*4)

 Note : Do not subject to strong vibration for long periods of time. 

25. Shock 
        endurance

490.3 m/s ( vertical, horizontal, once each 
face ) 

26. External 
              dimensions 

58(W) x 58(H) x 48(D) mm 

 

( not including lens and protrusions ) 

27.Mass 

Approx. 220g ( without lens ) 

 

12.

 

Sensitivity 

 selection 

AGC OFF/ON 

 

Manual Gain Adjustable at AGC OFF. 
Limit Gain Adjustable at AGC ON   
(0

Approx. 18dB) 

13.Electric shutter speed 

PRESET 

Select high speed shutter:OFF(1/60),1/100, 

 

1/250, 1/500, 1/1000, 1/2000, 

 

1/4000, 1/10000, 1/20000 

 1/30000, 

1/50000 

second 

 

(*2)

 low speed shutter:OFF(1/60),1/30, 

 

1/15, 1/10, 1/7.5, 1/6, 1/5, 1/3.75 

 

1/3, 1/2.5, 1/1.5, 1, 1.5, 2, 2.5, 3, 

 

3.5, 4, 4.5, 5, 5.5, 6, 6.5, 7, 7.5, 8 second 

 

(*2)

 

An image output becomes intermittent. 

VARIABLE 

Approx. 1H steps from 1/60 second to 1/10,000 
second 

AES 1/60 

sec 

 Approx.1/50000 sec 

 

From 1/60 second to approx. 1/50,000 second 
SLOW/NORMAL/FAST 

EXT. TRIG 

ONE trigger / Fixed shutter 

14.Auto level control[ALC] 
 AVERAGE 
 PEAK&AVERAGE 
 AREA 

 

 

(Scanning area is selectable from 9 area.) 

15.Auto-iris lens outputs 
 

Iris control voltage input (galvanometer) type lens
Damper  1150-ohm±10% 

Coupling coil 

impedance 

Drive     190-ohm±10% 

 

6

Video signal 

 output 

 

RGB output

RGB

 

  0.7 Vp-p/75-ohm  Positive 

SYNC (G on SYNC) 0.3 Vp-p    Negative 
MULTI connector (D-sub15) 

Y/C output 

(*1)

Y

 

     0.7 Vp-p/75-ohm  Positive 

 

SYNC   0.3 Vp-p  Negative 

 

C

 

     0.3 Vp-p(Burst)/75-ohm 

Subcarrier frequency  3.579545MHz 
MULTI connector ( D-sub15 ) 

VBS output 

(*1)

Video  0.7 Vp-p/75-ohm  Positive 

 

SYNC  0.3 Vp-p  Negative 
Burst 0.3 Vp-p    8 cycles 
Subcarrier frequency  3.579545MHz 
MULTI connector ( D-sub15 )/BNC 

7

Video signal   

processing 

Digital processing ( input 10 bits ) 

8

S/N ( Y signal ) 

More than 50dB   

 

( AGC, enhancer and gamma off ) 

9

Resolution  

Horizontal

 

440TV lines 

( Y signal at center )

Vertical

 

480 TV lines (350 TV lines(*)) 

 

 

10

Standard 

 sensitivity 

2,000 lx (F5.6, 100IRE) 

11

Minimum illumination 

 

10 lx ( F1.4, AGC ON, 50IRE ) 

 (*1)

Only at the NTSC mode

 

1

Imaging device 

1/2-inch progressive scan interline CCD 

Total number of 
                    pixels 

692(H) x 504(V) 

No. of effective 

 pixels 

659(H) x 494(V) 

Unit cell size 

9.9(H) x 9.9(V)

μ

m ( Square pixel ) 

Color filter 

R, G, B primary color mosaic filters on chip 

2

Scanning area 

6.52(H) x 4.89(V)mm 

3

Scanning 

 system 

Progressive scan ( VGA mode ) 

(Switch change) 

2:1 interlace scan ( NTSC mode ) 

4

Frequency 

Horizontal  31.468kHz (15.734kHz

(*1)

 )

±

0.5Hz 

 

Vertical          59.94Hz 

5

Sync system 

Internal / external ( HD/VD auto selection 

(*1)

 )   

Internal sync 

output 

 

HD 31.468kHz 

(15.734kHz 

(*1)

)

±

0.5Hz 

(Switch change) 

2Vp-p/75-ohm or 5Vp-p      Negative 

VD 59.94Hz 

(Switch change) 

2Vp-p/75-ohm or 5Vp-p      Negative 

SYNC 

2Vp-p/75-ohm  Negative 

WEN 

5Vp-p  Negative 

External sync 

                    input 

 

HD 31.468kHz 

(15.734kHz 

(*1)

 )

±

0.5Hz   

 

2

5Vp-p   Negative 

VD 

59.94Hz        2

5Vp-p  Negative 

TRIG 

Low 0 Vdc    High 2

5Vdc 

 

Main specifications 

 
 
 
 
 
 
 
 
 

Содержание KP-FD30

Страница 1: ...Hitachi Kokusai Electric Inc MGA2700 Thank you for procuring this fine Hitachi Kokusai Electric color CCD camera Before using the camera please read this operation manual carefully and keep this manual on file for ready reference in the future ...

Страница 2: ......

Страница 3: ...at it will take several seconds until a picture is displayed on the monitor after power on Handling Do not attempt to remove cover When installing or removing a lens be sure to use care that water or dust does not enter the inside of the camera Installing and storage Avoid installing or storing the camera in the following environments Environments exposed to direct sunlight rain or snow Environmen...

Страница 4: ...output of NTSC system by Switch change Features General Camera with C mount adaptor Operation manual Optional accessories DC input plug R03 P3F R03 P3F Lens plug E4 191J 100 E4 191J 100 MULTI cable plug KEC 15P Housing JK SP2140 Pin cntact JK C151C Cover Composition C mount adaptor When using a CS mount lens remove the C mount adaptor Lens mount ring Lens mount screws Set up buttons SET UP DOWN Vi...

Страница 5: ...Unit mm Connections EXP VGA progressive scan mode External View ...

Страница 6: ...lly adjust for best focus 6 Finally tighten the lens mount screws Lens DC control voltage galvanometer system should be used for an automatic iris lens Although arrangement of a lens connector is based on JEITA the length of the cable between the main part of a lens and a plug is required 150mm or more Flangeback adjustment Flangeback adjustment is needed in cases where focus cannot be obtained by...

Страница 7: ...EA Scanning area is selectable from 9 area 15 Auto iris lens outputs Iris control voltage input galvanometer type lens Damper 1150 ohm 10 Coupling coil impedance Drive 190 ohm 10 6 Video signal output RGB output RGB 0 7 Vp p 75 ohm Positive SYNC G on SYNC 0 3 Vp p Negative MULTI connector D sub15 Y C output 1 Y 0 7 Vp p 75 ohm Positive SYNC 0 3 Vp p Negative C 0 3 Vp p Burst 75 ohm Subcarrier freq...

Страница 8: ...e plug after turning off a camera power supply Remote Connection This camera can perform remote control of various setup of A camera with a personal computer Please perform wiring as shown in a figure to an optional remote plug and connect with the remote connector on the back of a camera after checking wiring correctly ...

Страница 9: ...cally after about 5 minutes Menu Operation 1 Main menu MAIN MENU Press the SET button for at least 2 seconds to display the main menu on the monitor screen Check the present settings at the main menu 2 Cameratitlemenu CAMERATITLEMENU One line of up to 24 alphanumeric characters can be displayed on the screen Camera title and a display position are set up Main menu Camera title setting menu Auto Le...

Страница 10: ...ume adjust 128 000 127 Return Return to the main menu End Return to the normal screen Press the Set button the numerals flash Press the Up and Down buttons to change the video level ALC MENU ZMODE AVE LEVEL 000 RET END 3 Auto level control ALCMENU Automatic light control mode is set up This control is reflected during automatic level control operation of an automatic iris diaphragm lens AGC AES et...

Страница 11: ...R SPEED 1 60 0 RET END The cautions at the time of slow shutter use Sensitivity goes up However the image is output is intermittent White flaws may become apparent at high Sensitivity these are not due to malfunction MODE PRESET Select electric shutter speed mode OFF PREST VARIABLE AES EXT TRIG Select preset shutter speed Press the Set button the numerals flash Press the Up and Down buttons to cha...

Страница 12: ...hite balance detection area Detect area positions 6 5 4 2 1 3 7 8 9 B GAIN OFFSET 000 RET END WHITE BALANCE MENU ZMODE AWC PRESET START PUSH SET R GAIN OFFSET 000 MODE AWC SUB MENU ZITEM PRESET SYNC MODE HD VD H PHASE 000 Camera initialize Press the Up and Down buttons simultaneously for 2 seconds to return the initial setting Press the Set button the numerals flash Press the Up and Down buttons t...

Страница 13: ... change Upper side 75 ohm termination Factory setting is Lower side No termination 75ohm termination 2 NTSC mode External HD External VD Sync output External HD External VD Sync output Even field Odd field Even field Odd field Screws Cautions Before removal of the back panel make sure that power is shut off to the camera Please remove the back panel carefully there is a FPC cable that is connected...

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ...lease input the trigger pulse of the following specification not to input a trigger pulse during the prohibition VSYN VD out Trigger 6 5 2nV 6 5 SYNC The period to falling rising of the following trigger should not be set to 2nV 2nV 2H from falling rising of a front trigger pulse V vertical synchronous period n integer External trigger signal prohibition period VSYN External trigger signal prohibi...

Отзывы: