Hitachi KP-FD30 Скачать руководство пользователя страница 3

Do not aim the camera lens at the sun. 

Do not shoot strong light or a scene including strong light. 
When such a scene is shot, vertical trailings will appear. 

    However, this is not due to failure. 
    In case strong Tight enters the camera through the lens,   

partial deterioration in picture quality will result. 

To obtain stable performance for long time 

    When the camera is used continuously for long time 
    under high ambient temperature, the inside electrical 
    parts become deteriorated, resulting in shortening its life. 

To use the camera continuously for long time, the 

    highest temperature must be below 40

Cleaning 

Use a blower or a lens brush to remove dusts on the 
lens or the optical filter. 

Wipe dirts on the case off with dry soft cloth. lf dirks 
are hardened, wipe them off with cloth moistened 
with neutral detergent liquid; wipe the cover with dry cloth. 

Do not use benzine,thinner,alcohol,liquid cleaner or 
spray-type cleaner. 

In event dust or other    debris    is lodged between the CCD 
and optical filter, consult dealer for cleaning by an optical 
technician. 

 

Power supply 

    Be sure to use the power source specified in the Major 
  Specifications. 

Before plugging or unplugging a connector, be sure 

    to turn off power. 
    To plug or unplug a connector, be sure to hold the 
  connector section. 

Note that it will take several seconds until a picture is 

    displayed on the monitor after power on. 

Handling 

Do not attempt to remove cover. 

When installing or removing a lens, be sure to use 

    care that water or dust does not enter the inside of. 
  the camera. 

Installing and storage 

    Avoid installing or storing the camera in the following 
  environments. 

Environments exposed to direct sunlight, rain or snow 

Environments where combustible or corrosive gas 

    exists 

Excessively warm or cold environment (Operating 

    ambient temperature: -10 to 50

Humid or dusty environment 

Place subjected to excessive vibration or shock 

Environment exposed to strong electric or magnetic field

 

 

Operating considerations

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2) Fixed pattern noise

  When the camera is operated in a high temperature, 

  fixed pattern noise may appear on the entire screen. 

 

Following are the phenomena inherent to a CCD imaging device, and not defects

1) Smear and blooming 

  When strong light (lamp, fluorescent lamp, reflected 
  light, etc.) is shot, pale bands are displayed vertically 
  above and below the light. 
  In this case, change the angle of the camera so that 
  such strong light does not enter the camera through 
 the lens. 

3) Moire 

  When fine patterns are shot, moire may be displayed. 
 

4) Burning 

  When excessively intense light comes to the 
  CCD for a long time, the spectral filter in the 
  CCD pixel may be deteriorated, and the colour of 
  the corresponding portion may change.   

Avoid using the camera under such condition.

 

Phenomena inherent to CCD imaging device

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание KP-FD30

Страница 1: ...Hitachi Kokusai Electric Inc MGA2700 Thank you for procuring this fine Hitachi Kokusai Electric color CCD camera Before using the camera please read this operation manual carefully and keep this manual on file for ready reference in the future ...

Страница 2: ......

Страница 3: ...at it will take several seconds until a picture is displayed on the monitor after power on Handling Do not attempt to remove cover When installing or removing a lens be sure to use care that water or dust does not enter the inside of the camera Installing and storage Avoid installing or storing the camera in the following environments Environments exposed to direct sunlight rain or snow Environmen...

Страница 4: ...output of NTSC system by Switch change Features General Camera with C mount adaptor Operation manual Optional accessories DC input plug R03 P3F R03 P3F Lens plug E4 191J 100 E4 191J 100 MULTI cable plug KEC 15P Housing JK SP2140 Pin cntact JK C151C Cover Composition C mount adaptor When using a CS mount lens remove the C mount adaptor Lens mount ring Lens mount screws Set up buttons SET UP DOWN Vi...

Страница 5: ...Unit mm Connections EXP VGA progressive scan mode External View ...

Страница 6: ...lly adjust for best focus 6 Finally tighten the lens mount screws Lens DC control voltage galvanometer system should be used for an automatic iris lens Although arrangement of a lens connector is based on JEITA the length of the cable between the main part of a lens and a plug is required 150mm or more Flangeback adjustment Flangeback adjustment is needed in cases where focus cannot be obtained by...

Страница 7: ...EA Scanning area is selectable from 9 area 15 Auto iris lens outputs Iris control voltage input galvanometer type lens Damper 1150 ohm 10 Coupling coil impedance Drive 190 ohm 10 6 Video signal output RGB output RGB 0 7 Vp p 75 ohm Positive SYNC G on SYNC 0 3 Vp p Negative MULTI connector D sub15 Y C output 1 Y 0 7 Vp p 75 ohm Positive SYNC 0 3 Vp p Negative C 0 3 Vp p Burst 75 ohm Subcarrier freq...

Страница 8: ...e plug after turning off a camera power supply Remote Connection This camera can perform remote control of various setup of A camera with a personal computer Please perform wiring as shown in a figure to an optional remote plug and connect with the remote connector on the back of a camera after checking wiring correctly ...

Страница 9: ...cally after about 5 minutes Menu Operation 1 Main menu MAIN MENU Press the SET button for at least 2 seconds to display the main menu on the monitor screen Check the present settings at the main menu 2 Cameratitlemenu CAMERATITLEMENU One line of up to 24 alphanumeric characters can be displayed on the screen Camera title and a display position are set up Main menu Camera title setting menu Auto Le...

Страница 10: ...ume adjust 128 000 127 Return Return to the main menu End Return to the normal screen Press the Set button the numerals flash Press the Up and Down buttons to change the video level ALC MENU ZMODE AVE LEVEL 000 RET END 3 Auto level control ALCMENU Automatic light control mode is set up This control is reflected during automatic level control operation of an automatic iris diaphragm lens AGC AES et...

Страница 11: ...R SPEED 1 60 0 RET END The cautions at the time of slow shutter use Sensitivity goes up However the image is output is intermittent White flaws may become apparent at high Sensitivity these are not due to malfunction MODE PRESET Select electric shutter speed mode OFF PREST VARIABLE AES EXT TRIG Select preset shutter speed Press the Set button the numerals flash Press the Up and Down buttons to cha...

Страница 12: ...hite balance detection area Detect area positions 6 5 4 2 1 3 7 8 9 B GAIN OFFSET 000 RET END WHITE BALANCE MENU ZMODE AWC PRESET START PUSH SET R GAIN OFFSET 000 MODE AWC SUB MENU ZITEM PRESET SYNC MODE HD VD H PHASE 000 Camera initialize Press the Up and Down buttons simultaneously for 2 seconds to return the initial setting Press the Set button the numerals flash Press the Up and Down buttons t...

Страница 13: ... change Upper side 75 ohm termination Factory setting is Lower side No termination 75ohm termination 2 NTSC mode External HD External VD Sync output External HD External VD Sync output Even field Odd field Even field Odd field Screws Cautions Before removal of the back panel make sure that power is shut off to the camera Please remove the back panel carefully there is a FPC cable that is connected...

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ...lease input the trigger pulse of the following specification not to input a trigger pulse during the prohibition VSYN VD out Trigger 6 5 2nV 6 5 SYNC The period to falling rising of the following trigger should not be set to 2nV 2nV 2H from falling rising of a front trigger pulse V vertical synchronous period n integer External trigger signal prohibition period VSYN External trigger signal prohibi...

Отзывы: