Hitachi KP-FD30 Скачать руководство пользователя страница 6

 

Note on lens selection

 

1)Observe the maximum size limit (A in the figure) 

When installing the lens. Internal damage can occur 
If a larger lens is used. 

2)Avoid using a lens that is heavier than the camera. 

If unavoidable, be sure to fix the lens itself on a support. 

 

Lens flange surface 

Fixed focus lens 

1)    Set the lens focus ring to infinity. 
2)    Aim toward an object at least 20 meters distant. 
3) 

Loosen the (2) lens mount screws and turn the lens 

        mount ring to adjust the focus.    Use care not to disturb 

    the lens focus ring. 

4)    Tighten the lens mount screws. 
 

Zoom lens 

1) 

Set the lens to telephoto and   

aim toward an object at least 
20 meters distant. 

2) 

Turn the lens focus ring to   

adjust the focus. 

3) 

Set the lens to wide angle.     

Loosen the (2) lens mount 

        screws and turn the lens mount ring to adjust the focus.   

Use care not to disturb the lens focus ring. 

4) 

Again set to telephoto but adjust the focus by turning the 

lend mount. 

5)    Repeat these steps and carefully adjust for best focus. 
6)    Finally, tighten the lens mount screws. 

 

Lens 

DC control voltage [galvanometer] system should be used for   
an automatic iris lens.   
Although arrangement of a lens connector is based on   
JEITA, the length of the cable between the main part of a   
lens and a plug is required 150mm or more.

 

Flangeback adjustment

 

Flangeback adjustment is needed in cases where focus cannot 
be obtained by normal lens focus operation or focus is lost at the
maximum telephoto and wide angle settings of a zoom lens. 
In such cases, open the lens iris and adjust as follows. 

 

A: Less than 4.1mm 

Lens 

● 

Multi connector

inch size screw

) 

 

 

 

 

 

 

 

 

 

 

 

 

 

                           

Plug

Housing( KEC-15P )

 

                                 

Pin contact ( JK-SP2140 )

 

                                 

Cover ( JK-C151C )

 

                     

● 

DC input connector

DC IN

] 

 

 

 

 

               

Plug

R03-P3F 

 

● 

Lens connector

LENS

] 

 

 

 

 

 

Plug

E4-191J-100 

   
 

Note: 

The length of a cable is required 
150mm or more. 

Pin No. 

Signal name

 

1 Damp(-) 

Damp(+) 

3 Drive(+) 
4 Drive(-) 

Pin No. 

Signal name

 

A GND 
B +12V 

input 

C N 

Pin No. 

Signal name 

1 R 

/(C)output 

2 G/Y 

output 

3 B 

/(VBS)output 

4 WE 

output 

5 GND 

(TXD/RXD) 

6 VIDEO 

GND 

7 VIDEO 

GND 

8 VIDEO 

GND 

UNREG +12V input 

10 TRIG 

input 

11 GND 
12 RXD 
13 

HD input / HD output / SYNC output

14 

VD input /VD output 

15 TXD 

 

Connectors

 

 
 
 
 

Содержание KP-FD30

Страница 1: ...Hitachi Kokusai Electric Inc MGA2700 Thank you for procuring this fine Hitachi Kokusai Electric color CCD camera Before using the camera please read this operation manual carefully and keep this manual on file for ready reference in the future ...

Страница 2: ......

Страница 3: ...at it will take several seconds until a picture is displayed on the monitor after power on Handling Do not attempt to remove cover When installing or removing a lens be sure to use care that water or dust does not enter the inside of the camera Installing and storage Avoid installing or storing the camera in the following environments Environments exposed to direct sunlight rain or snow Environmen...

Страница 4: ...output of NTSC system by Switch change Features General Camera with C mount adaptor Operation manual Optional accessories DC input plug R03 P3F R03 P3F Lens plug E4 191J 100 E4 191J 100 MULTI cable plug KEC 15P Housing JK SP2140 Pin cntact JK C151C Cover Composition C mount adaptor When using a CS mount lens remove the C mount adaptor Lens mount ring Lens mount screws Set up buttons SET UP DOWN Vi...

Страница 5: ...Unit mm Connections EXP VGA progressive scan mode External View ...

Страница 6: ...lly adjust for best focus 6 Finally tighten the lens mount screws Lens DC control voltage galvanometer system should be used for an automatic iris lens Although arrangement of a lens connector is based on JEITA the length of the cable between the main part of a lens and a plug is required 150mm or more Flangeback adjustment Flangeback adjustment is needed in cases where focus cannot be obtained by...

Страница 7: ...EA Scanning area is selectable from 9 area 15 Auto iris lens outputs Iris control voltage input galvanometer type lens Damper 1150 ohm 10 Coupling coil impedance Drive 190 ohm 10 6 Video signal output RGB output RGB 0 7 Vp p 75 ohm Positive SYNC G on SYNC 0 3 Vp p Negative MULTI connector D sub15 Y C output 1 Y 0 7 Vp p 75 ohm Positive SYNC 0 3 Vp p Negative C 0 3 Vp p Burst 75 ohm Subcarrier freq...

Страница 8: ...e plug after turning off a camera power supply Remote Connection This camera can perform remote control of various setup of A camera with a personal computer Please perform wiring as shown in a figure to an optional remote plug and connect with the remote connector on the back of a camera after checking wiring correctly ...

Страница 9: ...cally after about 5 minutes Menu Operation 1 Main menu MAIN MENU Press the SET button for at least 2 seconds to display the main menu on the monitor screen Check the present settings at the main menu 2 Cameratitlemenu CAMERATITLEMENU One line of up to 24 alphanumeric characters can be displayed on the screen Camera title and a display position are set up Main menu Camera title setting menu Auto Le...

Страница 10: ...ume adjust 128 000 127 Return Return to the main menu End Return to the normal screen Press the Set button the numerals flash Press the Up and Down buttons to change the video level ALC MENU ZMODE AVE LEVEL 000 RET END 3 Auto level control ALCMENU Automatic light control mode is set up This control is reflected during automatic level control operation of an automatic iris diaphragm lens AGC AES et...

Страница 11: ...R SPEED 1 60 0 RET END The cautions at the time of slow shutter use Sensitivity goes up However the image is output is intermittent White flaws may become apparent at high Sensitivity these are not due to malfunction MODE PRESET Select electric shutter speed mode OFF PREST VARIABLE AES EXT TRIG Select preset shutter speed Press the Set button the numerals flash Press the Up and Down buttons to cha...

Страница 12: ...hite balance detection area Detect area positions 6 5 4 2 1 3 7 8 9 B GAIN OFFSET 000 RET END WHITE BALANCE MENU ZMODE AWC PRESET START PUSH SET R GAIN OFFSET 000 MODE AWC SUB MENU ZITEM PRESET SYNC MODE HD VD H PHASE 000 Camera initialize Press the Up and Down buttons simultaneously for 2 seconds to return the initial setting Press the Set button the numerals flash Press the Up and Down buttons t...

Страница 13: ... change Upper side 75 ohm termination Factory setting is Lower side No termination 75ohm termination 2 NTSC mode External HD External VD Sync output External HD External VD Sync output Even field Odd field Even field Odd field Screws Cautions Before removal of the back panel make sure that power is shut off to the camera Please remove the back panel carefully there is a FPC cable that is connected...

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ...lease input the trigger pulse of the following specification not to input a trigger pulse during the prohibition VSYN VD out Trigger 6 5 2nV 6 5 SYNC The period to falling rising of the following trigger should not be set to 2nV 2nV 2H from falling rising of a front trigger pulse V vertical synchronous period n integer External trigger signal prohibition period VSYN External trigger signal prohibi...

Отзывы: