375
The receiver warm up sequence while decoding when all warm up settings are enabled is shown in
figure 12-9.
Warm Up
Off Time
Warm Up
Time 1
Warm Up
Time 2
Warm Up
Time 3
Warm Up
Time 4
Warm Up
Time5
RECEIVER
CONTROL
LINE SETTING
Off
Warm Up
Setting 1
Warm Up
Setting 2
Warm Up
Setting 3
Warm Up
Setting 4
Warm Up
Setting 5
1600sps or 3200sps
Sync Setting
Possible
LOBAT
Check
Possible
LOBAT
Check
Possible
LOBAT
Check
Possible
LOBAT
Check
Possible
LOBAT
Check
Possible
LOBAT
Check
EXTS1 & EXTS0
signals are
expected to be
valid here.
160 ms
Figure 12-9 Automatic Receiver Warm Up Sequence
3. Host Initiated Receiver Warm Up Sequence
The host can cause the FLEX decoder to warm-up the receiver
in three ways: (1) by turning on the
FLEX decoder by setting the ON bit in the control packet;
(2) by requesting a noise detect by
setting the SND bit in the roaming control packet; or (3) by requesting an A-word search by
setting the SAS bit in the roaming control packet. When the FLEX decoder warms up the receiver
in response to a host request, the first warm up setting, if enabled, is applied to the receiver control
lines for the amount of time programmed for that setting. Each subsequent warm up setting is
applied to the receiver control lines for their corresponding time until a disabled warm up setting is
found. Once a disabled warm up setting is found, the “3200sps Sync Setting”
(for ON and SND
warm ups) or the “1600sps Sync Setting” (for SAS warm ups) is applied to the receiver control
lines and the decoder does not expect valid signal until after the “3200sps Sync Warm Up Time”
(for ON, SND, and SAS warm ups) has expired. In figure 12-10 the receiver warm up sequence
when the host initiates a warm-up sequence and when all warm up settings are enabled is shown.
Warm Up
Time 1
Warm Up
Time 2
Warm Up
Time 3
Warm Up
Time 4
Warm Up
Time5
Warm Up
Time
Sync
3200sps
RECEIVER
CONTROL
LINE SETTING
Off
Warm Up
Setting 1
Warm Up
Setting 2
Warm Up
Setting 3
Warm Up
Setting 4
Warm Up
Setting 5
3200sps
Sync Setting
Possible
LOBAT
Check
Possible
LOBAT
Check
Possible
LOBAT
Check
Possible
LOBAT
Check
Possible
LOBAT
Check
Possible
LOBAT
Check
EXTS1 & EXTS0
signals are
expected to be
valid here.
Figure 12-10 Host Initiated Receiver Warm Up Sequence
Содержание H8/3935
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 24: ...12 ...
Страница 53: ...41 Notation op Operation field 15 0 8 7 op op Figure 2 10 Block Data Transfer Instruction Code ...
Страница 96: ...84 ...
Страница 142: ...130 ...
Страница 144: ...132 ...
Страница 252: ...240 ...
Страница 326: ...314 ...
Страница 340: ...328 ...
Страница 520: ...508 ...