275
Table 10-9 Examples of BRR Settings for Various Bit Rates (Synchronous Mode) (2)
OSC
10 MHz
16 MHz
Bit Rate (bit/s) n
N
Error
n
N
Error
200
—
—
—
—
—
—
250
—
—
—
3
124
0
300
—
—
—
—
—
—
500
—
—
—
2
249
0
1k
—
—
—
2
124
0
2.5k
—
—
—
2
49
0
5k
0
249
0
2
24
0
10k
0
124
0
0
199
0
25k
0
49
0
0
79
0
50k
0
24
0
0
39
0
100k
—
—
—
0
19
0
250k
0
4
0
0
7
0
500k
—
—
—
0
3
0
1M
—
—
—
0
1
0
Blank: Cannot be set.
— : A setting can be made, but an error will result.
*
: Continuous transmission/reception is not possible.
Notes: The value set in BRR is given by the following equation:
N=
OSC
(8
×
2
2n
×
B)
— 1
where
B: Bit rate (bit/s)
N: Baud rate generator BRR setting (0
≤
N
≤
255)
OSC: Value of ø
OSC
(Hz)
n: Baud rate generator input clock number (n = 0, 2, or 3)
(The relation between n and the clock is shown in table 10-10.)