5 - 19
Disassembly and Reassembly > Disassembly
(22) Lens Frame, Lens Unit, Cushion and Crystal Filter
[For DZ-GX3300E]
1) Disconnect the fl at cable.
2) Remove the screw [C].
3) Turn the GSL-3M circuit board (e) up in the
direction of the arrow.
4) Remove the two screws [D].
5) Remove the screw [C] and then remove the
lens frame (a).
6) Remove the two screws [F] and then remove
the cushion (c) and the crystal fi lter (d) from
the lens unit (b).
Note:
1) The lens unit and crystal fi lter are precision
components: Take great care when handling
them. Adherence of any dust, foreign object,
fi ngerprint, etc. to them, or any scratches or
impact, could cause a fault.
2) Never use metal tweezers to handle the
crystal
fi lter: Doing so could damage it.
Cautions during disassembly and reassembly:
Take care with the orientation of crystal
fi lter when assembling it: Incorrect
orientation of the crystal fi lter could cause a
fault.
4) [D]
5) [C]
(a)
(b)
(c)
(d)
(e)
2) [C]
6) [F]
6) [F]
3)
1)
[C] M1.7×3 (Silver)
[D] M1.7×4 (Black)
[F] M1.7×5 (Silver)
Fig. 5-3-22
(a) Lens frame
(b) Lens unit
(c) Cushion
(d) Crystal fi lter
(e) GSL-3M circuit board
(23) CCD Image Sensor and GSL-3M Circuit Board
[For DZ-GX3300E]
1) Unsolder the 26 points at the CCD image
sensor (a) terminal on GSL-3M circuit board
(b).
Note:
The CCD image sensor is a precision
component: Take great care when handling it.
Adherence of any dust, foreign object,
fi ngerprint, etc. to it, or any scratches or
impact, could cause a fault.
1)
(a)
(b)
Fig. 5-3-23
(a) CCD image sensor
(b) GSL-3M circuit board