Troubleshooting
17–7
Hitachi Unified Storage Hardware Service Guide
Is the storage system configured to use
the DHCPv4 server?
When the storage system is configured to
use a DHCPv4 server, use the IP
addresses assigned by the DHCP v4
server. When using a DHCP v4 server, we
recommend you configure the storage
system to use static IP addresses.
If the IP address is not assigned by a
DHCP v4 server, but the storage system
is configured to use DHCP v4 server-
supplied IP addresses, Storage Navigator
Modular 2 will not be able to connect to
the storage system. Consult your
administrator and review the DHCP v4
server settings.
[default value]
DHCP v4:Off (Static IP Address)
Is the IP address of the storage system
assigned to other storage systems or
hosts?
If a storage system uses the same IP
address used by other storage systems
and hosts, Storage Navigator Modular 2
cannot connect to the storage system.
Assign different unused IP addresses to
the storage system.
Are the correct values set for the IP
address, subnet mask, or default
gateway of the host where Storage
Navigator Modular 2 is installed?
Set the IP address, subnet mask and
default gateway that allows the storage
system to communicate with the host.
Is the network switch performing TCP/
UDP port filtering?
The default TCP port number for Storage
Navigator Modular 2 is 2000. Set a
suitable value for the customer
environment.
[the default port
number]:2000(standard) 28355(secure)
Change the port number in environments
that use the Cisco SIP Phone.
Is the Search Array function being
performed across the IPv6 routers?
The Auto Search Array used by IPv6 uses
link-local scope multicast. The IPv6
router cannot transfer this multicast to
other local links, so the IPv6 router is
unable to search the storage system
across the IPv6 router. If different local
links are used, register the storage
system using a static IP address search.
Is packet filtering enabled?
There may be times when a connection to
the storage system cannot be made
temporarily. Wait at least one minute,
and then update it again.
Table 17-1: Correcting Storage Navigator Modular 2 problems
Item to check
Description
Содержание CBL
Страница 12: ...xii Hitachi Unified Storage Hardware Service Guide Serial Numbers Hitachi Unified Storage Models 110 and 130 ...
Страница 13: ...xiii Hitachi Unified Storage Hardware Service Guide Labels on the CBXSS Either a or b is affixed ...
Страница 14: ...xiv Hitachi Unified Storage Hardware Service Guide Labels on the CBXSL Either a or b is affixed a b ...
Страница 15: ...xv Hitachi Unified Storage Hardware Service Guide Labels on the CBSS Either a or b is affixed a b ...
Страница 16: ...xvi Hitachi Unified Storage Hardware Service Guide Labels on the CBSL Either a or b is affixed a b ...
Страница 17: ...xvii Hitachi Unified Storage Hardware Service Guide Labels on the CBL CBLE CBLD Either a or b is affixed a b ...
Страница 18: ...xviii Hitachi Unified Storage Hardware Service Guide Labels on the DBS DBSD Either a or b is affixed a b ...
Страница 19: ...xix Hitachi Unified Storage Hardware Service Guide Labels on the DBL DBLD Either a or b is affixed a b ...
Страница 20: ...xx Hitachi Unified Storage Hardware Service Guide Labels on the CBXSS ...
Страница 21: ...xxi Hitachi Unified Storage Hardware Service Guide Labels on the DBF Either a or b is affixed a b ...
Страница 22: ...xxii Hitachi Unified Storage Hardware Service Guide Labels on the DBX Either a or b is affixed kg a b a b ...
Страница 23: ...xxiii Hitachi Unified Storage Hardware Service Guide Labels on front of the DBW added on April 2014 ...
Страница 25: ...xxv Hitachi Unified Storage Hardware Service Guide Labels on rear of the DBW added on April 2014 ...
Страница 28: ...xxviii Hitachi Unified Storage Hardware Service Guide DBX DBW Labels on cache backup battery CBL CBLE CBLD ...
Страница 30: ...xxx Hitachi Unified Storage Hardware Service Guide CBL CBLE CBLD DBS DBSD DBL DBLD DBF ...
Страница 35: ...xxxv Hitachi Unified Storage Hardware Service Guide Labels on Management Module CBL CBLE CBLD LAN UPS ...
Страница 36: ...xxxvi Hitachi Unified Storage Hardware Service Guide Labels on I O Module ENC DBS DBSD DBL DBLD DBF ...
Страница 37: ...xxxvii Hitachi Unified Storage Hardware Service Guide DBW Labels on I O Card ENC DBX Labels on Host Connector ...
Страница 38: ...xxxviii Hitachi Unified Storage Hardware Service Guide Labels on SAS ENC Cable Labels on cable holder DBX In ...
Страница 39: ...xxxix Hitachi Unified Storage Hardware Service Guide Out ...
Страница 40: ...xl Hitachi Unified Storage Hardware Service Guide ...
Страница 126: ...3 8 Procedures before and after replacing components Hitachi Unified Storage Hardware Service Guide ...
Страница 152: ...5 8 Replacing a cache backup battery Hitachi Unified Storage Hardware Service Guide ...
Страница 156: ...6 4 Replacing a Fan Module Hitachi Unified Storage Hardware Service Guide ...
Страница 180: ...8 16 Adding and replacing controllers Hitachi Unified Storage Hardware Service Guide ...
Страница 188: ...9 8 Replacing cache memory Hitachi Unified Storage Hardware Service Guide ...
Страница 200: ...11 6 Replacing the Host connector Hitachi Unified Storage Hardware Service Guide ...
Страница 204: ...12 4 Replacing the Drive I O Module Hitachi Unified Storage Hardware Service Guide ...
Страница 212: ...14 4 Replacing the SAS ENC cable Hitachi Unified Storage Hardware Service Guide ...
Страница 274: ...17 14 Troubleshooting Hitachi Unified Storage Hardware Service Guide ...
Страница 286: ...Glossary 12 Hitachi Unified Storage Hardware Service Guide A B C D E F G H I J K L M N O P Q R S T U V W X Y Z ...
Страница 290: ...Index 4 Hitachi Unified Storage Hardware Service Guide U Upgrading Hitachi Unified Storage 130 15 1 ...
Страница 291: ...1 Hitachi Unified Storage Hardware Service Guide ...