Upgrading a Hitachi Unified Storage 130 system
15–19
Hitachi Unified Storage Hardware Service Guide
2. On the CBSL or CBSS, press the main switch on either Controller #0 or
Controller #1 for three seconds or more using a pen or similar object.
The CBSS/CBSL green C-PWR LED blinks for three seconds and then
goes ON.
3. If a DBW is connected to the CBSL or CBSS, turn off the Power Switch.
However, if the power interlock mode is set to the UPS interlock mode1/
2/3, remove the UPS interlock cable connected to the CBSL/CBSS, and
then turn off the main switch.
4. Confirm that the POWER LED on the front of the storage system
changes from green to orange (this should take approximately 10
minutes).
- The
green
READY LED on the DBL/DBS/DBX does not go OFF
when the main switch is turned off in the Maintenance mode. This
is normal and does not indicate a problem.
- The
green
ACT LED on a drive might continue to blink after the
orange POWER LED goes ON. This is normal and does not indicate
a problem.
5. Power off the storage system as follows:
- If the storage system power cables are connected to a PDB, check
whether other devices, such as switches, are also connected to the
PDB.
If the storage system is the only device connected to the PDB, power
off the circuit breakers of the PDB.
If other devices are connected to the PDB, check whether they can
be powered off. If they cannot be powered off, remove two power
cables (four power cables for DBX) from the power units of the
Controller Box and Drive Box.
- If the power cables are connected to something other than a PDB,
remove two power cables (four power cables for DBX) of the
Controller Box and Drive Box, or turn off the input power.
6. Remove all Fibre Channel and iSCSI cables from the rear of the CBSL/
CBSS. Leave the other end of the cables connected to their respective
devices.
Removing power cables
After you shut down the storage system, remove the power cables from the
Hitachi Unified Storage 130.
1. Remove the Hitachi Unified Storage 130 front bezel (see
replacing the front bezel on page 3-10
).
2. Remove all power cables from the Hitachi Unified Storage 130.
NOTE: When you remove the UPS interlock cable, an email alert
notification is sent (if configured in Hitachi Storage Navigator Modular 2)
and a TRAP is received by the SNMP Agent Support Function.
Содержание CBL
Страница 12: ...xii Hitachi Unified Storage Hardware Service Guide Serial Numbers Hitachi Unified Storage Models 110 and 130 ...
Страница 13: ...xiii Hitachi Unified Storage Hardware Service Guide Labels on the CBXSS Either a or b is affixed ...
Страница 14: ...xiv Hitachi Unified Storage Hardware Service Guide Labels on the CBXSL Either a or b is affixed a b ...
Страница 15: ...xv Hitachi Unified Storage Hardware Service Guide Labels on the CBSS Either a or b is affixed a b ...
Страница 16: ...xvi Hitachi Unified Storage Hardware Service Guide Labels on the CBSL Either a or b is affixed a b ...
Страница 17: ...xvii Hitachi Unified Storage Hardware Service Guide Labels on the CBL CBLE CBLD Either a or b is affixed a b ...
Страница 18: ...xviii Hitachi Unified Storage Hardware Service Guide Labels on the DBS DBSD Either a or b is affixed a b ...
Страница 19: ...xix Hitachi Unified Storage Hardware Service Guide Labels on the DBL DBLD Either a or b is affixed a b ...
Страница 20: ...xx Hitachi Unified Storage Hardware Service Guide Labels on the CBXSS ...
Страница 21: ...xxi Hitachi Unified Storage Hardware Service Guide Labels on the DBF Either a or b is affixed a b ...
Страница 22: ...xxii Hitachi Unified Storage Hardware Service Guide Labels on the DBX Either a or b is affixed kg a b a b ...
Страница 23: ...xxiii Hitachi Unified Storage Hardware Service Guide Labels on front of the DBW added on April 2014 ...
Страница 25: ...xxv Hitachi Unified Storage Hardware Service Guide Labels on rear of the DBW added on April 2014 ...
Страница 28: ...xxviii Hitachi Unified Storage Hardware Service Guide DBX DBW Labels on cache backup battery CBL CBLE CBLD ...
Страница 30: ...xxx Hitachi Unified Storage Hardware Service Guide CBL CBLE CBLD DBS DBSD DBL DBLD DBF ...
Страница 35: ...xxxv Hitachi Unified Storage Hardware Service Guide Labels on Management Module CBL CBLE CBLD LAN UPS ...
Страница 36: ...xxxvi Hitachi Unified Storage Hardware Service Guide Labels on I O Module ENC DBS DBSD DBL DBLD DBF ...
Страница 37: ...xxxvii Hitachi Unified Storage Hardware Service Guide DBW Labels on I O Card ENC DBX Labels on Host Connector ...
Страница 38: ...xxxviii Hitachi Unified Storage Hardware Service Guide Labels on SAS ENC Cable Labels on cable holder DBX In ...
Страница 39: ...xxxix Hitachi Unified Storage Hardware Service Guide Out ...
Страница 40: ...xl Hitachi Unified Storage Hardware Service Guide ...
Страница 126: ...3 8 Procedures before and after replacing components Hitachi Unified Storage Hardware Service Guide ...
Страница 152: ...5 8 Replacing a cache backup battery Hitachi Unified Storage Hardware Service Guide ...
Страница 156: ...6 4 Replacing a Fan Module Hitachi Unified Storage Hardware Service Guide ...
Страница 180: ...8 16 Adding and replacing controllers Hitachi Unified Storage Hardware Service Guide ...
Страница 188: ...9 8 Replacing cache memory Hitachi Unified Storage Hardware Service Guide ...
Страница 200: ...11 6 Replacing the Host connector Hitachi Unified Storage Hardware Service Guide ...
Страница 204: ...12 4 Replacing the Drive I O Module Hitachi Unified Storage Hardware Service Guide ...
Страница 212: ...14 4 Replacing the SAS ENC cable Hitachi Unified Storage Hardware Service Guide ...
Страница 274: ...17 14 Troubleshooting Hitachi Unified Storage Hardware Service Guide ...
Страница 286: ...Glossary 12 Hitachi Unified Storage Hardware Service Guide A B C D E F G H I J K L M N O P Q R S T U V W X Y Z ...
Страница 290: ...Index 4 Hitachi Unified Storage Hardware Service Guide U Upgrading Hitachi Unified Storage 130 15 1 ...
Страница 291: ...1 Hitachi Unified Storage Hardware Service Guide ...