3–4
Procedures before and after replacing components
Hitachi Unified Storage Hardware Service Guide
• Do not block or cover the openings of the storage system hardware.
Never place a unit near a radiator or heat register. Failure to follow
these guidelines can cause overheating and affect the unit’s reliability.
• After a component has been replaced, secure the chassis cover to the
storage system. The chassis is designed to let cooling air flow
effectively within it. An open chassis allows air leaks that might
interrupt and redirect the flow of cooling air from internal components.
• Do not make mechanical or electrical modifications or repairs to the
equipment. Such actions can cause an electric shock or cause the
storage system to malfunction. Hitachi is not responsible for regulatory
compliance of a modified Hitachi product.
• When removing cables, hold the cable connector and leave enough
slack in the cables, so they do not bend to a diameter of less than 76
mm (3") or a radius less than 38 mm (1.5") when extended and do not
become pinched when retracted.
• A DBW can reach 80 dB at a temperature of 32°C, with a maximum
decibel level of 85dB. When a DBW is connected to a CBL, refrain from
working on the DBW for a prolonged period of time.
Guidelines to follow when replacing a component
Observe the following guidelines when replacing a component in Hitachi
Unified Storage systems.
• Replace components after the green READY LED on the controller front
panel goes ON.
• Use only the replacement parts specified in this guide.
• Do not perform maintenance when the green READY LED on the
controller front panel blinks quickly because the ENC firmware is being
downloaded. Wait for the READY LED on the Controller Box to go ON
before performing maintenance (wait time can be up to 50 minutes, 60
minutes for the CBL, or 180 minutes if the DBW is connected to the
CBL).
• If you turn on a single controller and the orange WARNING LED on the
controller front panel blinks quickly, do not perform maintenance. Wait
for the WARNING LED to go OFF and the green READY LED to go ON
(30-to-85 minutes) before performing maintenance.
• If an allowable time limit for replacing a component is specified in the
replacement instructions, observe the time limit.
• When replacing a drive, controller, Host I/O Board, Host I/O Module,
cache backup battery, Drive I/O Module, I/O Module (ENC), Fan
module, or Power Unit with the storage system powered on, wait at
least 30 seconds before replacing the failed component.
If the storage system is turned on, complete the replacement within 10
minutes. Otherwise, a power-off (system-down) condition can occur.
If a Power Unit and another module fail at the same time, replace the
Power Unit first and then replace the module. Otherwise, a power-off
(system-down) condition can occur.
Содержание CBL
Страница 12: ...xii Hitachi Unified Storage Hardware Service Guide Serial Numbers Hitachi Unified Storage Models 110 and 130 ...
Страница 13: ...xiii Hitachi Unified Storage Hardware Service Guide Labels on the CBXSS Either a or b is affixed ...
Страница 14: ...xiv Hitachi Unified Storage Hardware Service Guide Labels on the CBXSL Either a or b is affixed a b ...
Страница 15: ...xv Hitachi Unified Storage Hardware Service Guide Labels on the CBSS Either a or b is affixed a b ...
Страница 16: ...xvi Hitachi Unified Storage Hardware Service Guide Labels on the CBSL Either a or b is affixed a b ...
Страница 17: ...xvii Hitachi Unified Storage Hardware Service Guide Labels on the CBL CBLE CBLD Either a or b is affixed a b ...
Страница 18: ...xviii Hitachi Unified Storage Hardware Service Guide Labels on the DBS DBSD Either a or b is affixed a b ...
Страница 19: ...xix Hitachi Unified Storage Hardware Service Guide Labels on the DBL DBLD Either a or b is affixed a b ...
Страница 20: ...xx Hitachi Unified Storage Hardware Service Guide Labels on the CBXSS ...
Страница 21: ...xxi Hitachi Unified Storage Hardware Service Guide Labels on the DBF Either a or b is affixed a b ...
Страница 22: ...xxii Hitachi Unified Storage Hardware Service Guide Labels on the DBX Either a or b is affixed kg a b a b ...
Страница 23: ...xxiii Hitachi Unified Storage Hardware Service Guide Labels on front of the DBW added on April 2014 ...
Страница 25: ...xxv Hitachi Unified Storage Hardware Service Guide Labels on rear of the DBW added on April 2014 ...
Страница 28: ...xxviii Hitachi Unified Storage Hardware Service Guide DBX DBW Labels on cache backup battery CBL CBLE CBLD ...
Страница 30: ...xxx Hitachi Unified Storage Hardware Service Guide CBL CBLE CBLD DBS DBSD DBL DBLD DBF ...
Страница 35: ...xxxv Hitachi Unified Storage Hardware Service Guide Labels on Management Module CBL CBLE CBLD LAN UPS ...
Страница 36: ...xxxvi Hitachi Unified Storage Hardware Service Guide Labels on I O Module ENC DBS DBSD DBL DBLD DBF ...
Страница 37: ...xxxvii Hitachi Unified Storage Hardware Service Guide DBW Labels on I O Card ENC DBX Labels on Host Connector ...
Страница 38: ...xxxviii Hitachi Unified Storage Hardware Service Guide Labels on SAS ENC Cable Labels on cable holder DBX In ...
Страница 39: ...xxxix Hitachi Unified Storage Hardware Service Guide Out ...
Страница 40: ...xl Hitachi Unified Storage Hardware Service Guide ...
Страница 126: ...3 8 Procedures before and after replacing components Hitachi Unified Storage Hardware Service Guide ...
Страница 152: ...5 8 Replacing a cache backup battery Hitachi Unified Storage Hardware Service Guide ...
Страница 156: ...6 4 Replacing a Fan Module Hitachi Unified Storage Hardware Service Guide ...
Страница 180: ...8 16 Adding and replacing controllers Hitachi Unified Storage Hardware Service Guide ...
Страница 188: ...9 8 Replacing cache memory Hitachi Unified Storage Hardware Service Guide ...
Страница 200: ...11 6 Replacing the Host connector Hitachi Unified Storage Hardware Service Guide ...
Страница 204: ...12 4 Replacing the Drive I O Module Hitachi Unified Storage Hardware Service Guide ...
Страница 212: ...14 4 Replacing the SAS ENC cable Hitachi Unified Storage Hardware Service Guide ...
Страница 274: ...17 14 Troubleshooting Hitachi Unified Storage Hardware Service Guide ...
Страница 286: ...Glossary 12 Hitachi Unified Storage Hardware Service Guide A B C D E F G H I J K L M N O P Q R S T U V W X Y Z ...
Страница 290: ...Index 4 Hitachi Unified Storage Hardware Service Guide U Upgrading Hitachi Unified Storage 130 15 1 ...
Страница 291: ...1 Hitachi Unified Storage Hardware Service Guide ...