Figure 5-94 Removing the connection kit F/H
Installing a connection kit F/H
1
.
Put on an anti-static wrist strap.
2
.
If the connector cover is installed in the mezzanine slot #2, remove it
from the slot.
Figure 5-95 Removing the connector cover
3
.
Align the connector and guide holes of the connection board of the
connection kit F/H with the male connector and guide pins on the main
board of the server blade, respectively.
4
.
Push in the connection board into the server blade straight downward by
pushing the portion indicated Push, and then close the two latches.
5
.
Push in the connector into the PCI expansion blade straight downward by
pushing the portion indicated Push, and then close the latch.
5-76
Replacing parts
Hitachi Compute Blade 500 Series System Service Manual
Содержание CB 520A A1
Страница 26: ...xxvi Preface Hitachi Compute Blade 500 Series System Service Manual ...
Страница 152: ...4 64 Common process for replacement Hitachi Compute Blade 500 Series System Service Manual ...
Страница 294: ...6 12 Identifying RAID rebuild status Hitachi Compute Blade 500 Series System Service Manual ...
Страница 432: ...9 16 Updating firmware Hitachi Compute Blade 500 Series System Service Manual ...
Страница 439: ...Change LOM configuration 10 7 Hitachi Compute Blade 500 Series System Service Manual ...
Страница 442: ...10 10 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Страница 450: ...10 18 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Страница 464: ...11 14 Troubleshooting Hitachi Compute Blade 500 Series System Service Manual ...
Страница 465: ...Hitachi Compute Blade 500 Series System Service Manual ...