Restoring MAPS action settings of 16Gb FC switch module
To restore the MAPS action settings
1
.
Skip this step when the switch is 8Gb FC switch module or monitor mode
is Fabric mode.
Enter
mapsconfig --actions
followed by a space and MAPS action
settings separating with commas indicated by
mapsconfig --show
command before the replacement, and then press Enter key.
Enter
mapsconfig –-show
, and then press Enter key.
Confirm that displayed MAPS action settings are as same as the ones
before the replacement.
The MAPS action settings are RASLOG, SNMP, SW_CRITICAL,
SW_MARGINAL, and SFP_MARGINAL, at the maximum.
Backup/restore procedure
The configuration data of sever blade and management module is
automatically backed up to the local storages in the system.
The configuration data of switch module is NOT automatically backed up.
Hitachi strongly recommends that you should back up the data of the switch
module before starting replacement procedure.
4-30
Common process for replacement
Hitachi Compute Blade 500 Series System Service Manual
Содержание CB 520A A1
Страница 26: ...xxvi Preface Hitachi Compute Blade 500 Series System Service Manual ...
Страница 152: ...4 64 Common process for replacement Hitachi Compute Blade 500 Series System Service Manual ...
Страница 294: ...6 12 Identifying RAID rebuild status Hitachi Compute Blade 500 Series System Service Manual ...
Страница 432: ...9 16 Updating firmware Hitachi Compute Blade 500 Series System Service Manual ...
Страница 439: ...Change LOM configuration 10 7 Hitachi Compute Blade 500 Series System Service Manual ...
Страница 442: ...10 10 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Страница 450: ...10 18 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Страница 464: ...11 14 Troubleshooting Hitachi Compute Blade 500 Series System Service Manual ...
Страница 465: ...Hitachi Compute Blade 500 Series System Service Manual ...