ATTENTION:
A. When the indication of Ref. No. is "- -", the indication of I.U. Add. is also "- -". In such a case, I.U. Add.
can not be changed although the "
,
" (TEMP) switch is depressed.
B. Ref. No. with no indoor unit connected and I.U. Add. not connected are not indicated.
C. The indoor unit already set as the master unit is not indicated.
e. Setting Procedure
Depress the "RUN/STOP" switch after selecting indoor unit, the
indicated unit is set as the master unit, the "
!
" and "SET" the
indicator appear.
The
"
!
" indicator of zone turns ON when there is one or more group
with the master unit set.
f. Perform the master unit setting procedure b. to e. for each group and
zone.
CHECK
ZONE
GROUP
g. After completion of the master unit setting, change the mode to the
standard state by depressing "RESET" switch.
ZONE
GROUP
ZONE GROUP
#
When there is any group in operation (with "RUN" indicator ON), the "CHECK" mode is not available.
#
Only one indoor unit can be set as the master unit in one group. Other indoor unit can not be set as the master
unit for the group with the master unit set already. For setting the master unit as the master unit for another
group, cancel the present master unit setting and perform the setting for another group.
#
In case that there are indoor units with auto-louver and indoor units without auto-louver in the same group, set the
indoor unit with auto-louver as the master unit. If the indoor unit without auto-louver is set as the master unit, the
auto-louver setting is not available for all the units of the group.
#
When setting the remote control switch group without transmission line between indoor units, the indoor unit
connected with the remote control switch shall be set as master unit.
(3) Cancellation of Master Unit Setting
a. Screen Change for Cancellation of Master Unit Setting
Keep depressing the "CHECK" switch for 3 seconds during all the
indoor unit is stopped (with "RUN" indicator OFF). The "CHECK"
indicator turns ON, and it shows the state is changed to the CHECK
mode. And "1" (master unit setting mode) turns ON at the 7-segment
indicator for checking.
b. Select of Zone To Be Canceled
Depress the "ZONE" switch and the "GROUP" V
V
switch, and select
the zone and the group to cancel.
c. Cancel the slave unit setting.
Depress the "RUN/STOP" switch and the master unit is canceled.
The "SET" indicator and the "
!
" indicators of group turn OFF.
The
"
!
" indicators of zone turns OFF when there is one or more
group with the master unit set.
SET
CHECK
ZONE
GROUP
SET
CHECK
ZONE
GROUP
SET
CHECK
ZONE
GROUP
d. Perform the cancellation of master unit setting procedure b. and c. for
each zone and group.
e. After completion of canceling the master unit setting, change the
mode to the standard state by depressing "RESET" switch.
GROUP
ZONE
GROUP
ZONE
HYJE-D02H
127
Содержание HYE-W01
Страница 7: ......
Страница 9: ......
Страница 16: ...Model HYXE J01H Wired Remote Control Switch 7 ...
Страница 22: ...Model HYDE E01H 7 Day Timer 13 ...
Страница 24: ...Model HCCS H128H2C1YM HCCS H128H2C1NM Central Control 15 ...
Страница 25: ...Model HCCS H247R4C1E Central Control 16 ...
Страница 26: ...Model HYJ J01H Central Control 17 ...
Страница 27: ...Central Control Model HYJM S01H 18 ...
Страница 34: ...HYXE G01H 25 ...
Страница 35: ...HYXE G01H 26 ...
Страница 46: ...HYXE J01H 37 ...
Страница 47: ...HYXE J01H 38 ...
Страница 48: ...HYXE J01H 39 ...
Страница 49: ...HYXE J01H 40 ...
Страница 50: ...HYXE J01H 41 ...
Страница 51: ...HYXE J01H 42 ...
Страница 52: ...HYXE J01H 43 ...
Страница 53: ...HYXE J01H 44 ...
Страница 54: ...HYXE J01H 45 ...
Страница 55: ...HYXE J01H 46 ...
Страница 56: ...HYXE J01H 47 ...
Страница 57: ...HYXE J01H 48 ...
Страница 58: ...HYXE J01H 49 ...
Страница 59: ...HYXE J01H 50 ...
Страница 60: ...HYXE J01H 51 ...
Страница 61: ...HYXE J01H 52 ...
Страница 62: ...HYXE J01H 53 ...
Страница 63: ...HYXE J01H 54 ...
Страница 64: ...HYXE J01H 55 ...
Страница 65: ...HYXE J01H 56 ...
Страница 66: ...HYXE J01H 57 ...
Страница 67: ...HYXE J01H 58 ...
Страница 68: ...HYXE J01H 59 ...
Страница 69: ...HYXE J01H 60 ...
Страница 70: ...HYXE J01H 61 ...
Страница 71: ...HYXE J01H 62 ...
Страница 72: ...HYXE J01H 63 ...
Страница 73: ...HYXE J01H 64 ...
Страница 74: ...HYXE J01H 65 ...
Страница 75: ...HYXE J01H 66 ...
Страница 76: ...HYXE J01H 67 ...
Страница 115: ...HYDEͲE01H Hisense HYDE E01H 106 ...
Страница 116: ...HYDE E01H 107 ...
Страница 117: ...HYDE E01H 108 ...
Страница 119: ...HYXE A01H HYJE D02H HYXE A01H HYXE A01H HYXE A01H HYJE D02H HYJE D02H HYJE D02H HYDE E01H 110 ...
Страница 120: ...HYXE A01H HYJE D02H HYDE E01H 111 ...
Страница 121: ...HYDE E01H 112 ...
Страница 122: ...HYDE E01H 113 ...
Страница 123: ...HYDE E01H 114 ...
Страница 124: ...HYXE A01H HYJE D02H HYDE E01H 115 ...
Страница 125: ...HYXE A01H HYJE D02H HYDE E01H 116 ...
Страница 126: ...HYJE D02H HYDE E01H 117 ...
Страница 127: ...HYDE E01H 118 ...
Страница 128: ...HYJE D02H HYXE A01H HYDE E01H 119 ...
Страница 129: ...HYJE D02H HYJE D02H HYXE A01H Hisense Hisense HYDE E01H 120 ...
Страница 173: ...HYJ J01H 164 ...
Страница 174: ...HYJ J01H 165 ...
Страница 175: ...HYJ J01H 166 ...
Страница 176: ...HYJ J01H 167 ...
Страница 177: ...HYJ J01H 168 ...
Страница 178: ...HYJ J01H 169 ...
Страница 179: ... R QRW KDV WKLV IXQFWLRQ DV HW HYJ J01H 170 ...
Страница 180: ...HYJ J01H 171 ...
Страница 181: ...HYJ J01H 172 ...
Страница 182: ...HYJ J01H 173 ...