HY
J
E-
D
0
2H
E. Prohibiting Operation by Remote Control Switch
<Function>
To prohibit the operation by the remote control switch.
When this function is available, the "CENTRAL" indication appears on the LCD on the remote control switch and
the operation by the remote control switch is not available.
1. Depress the "ZONE" switch and the "GROUP" switch and select
the setting target.
(Refer to item 2 of "A. Setting Target Selection and Monitoring
Unit Operation Status" .)
The above
fi
gure shows the case of selecting
"ZONE 3, GROUP 6".
2. Depress the "RMT. SW NAVAL" switch. Every time the "RMT.
SW NAVAL" switch is depressed, the "RMT. SW NAVAL"
indication is turned ON and OFF alternately.
ATTENTION:
A. The above indications show the case of setting operation mode for "ZONE 3, GROUP 6".
The same setting procedure shall be performed for other groups.
B. Although the "RMT. SW NAVAL" function is set, in case of operation by the central station, the unit can be
stopped by the remote control switch, and in this case, the unit can be started again by the remote control switch.
C. For the unit without remote control switch, the "RMT. SW NAVAL" function shall be set.
D. In case of using together with other controllers, do not set the "RMT. SW NAVAL" function. Additionally, do not
set the "RMT. SW NAVAL" function by other controller or the malfunction may occur.
E. In case of no setting of temperature ("- -"), the temperature can be set by the remote control switch during the “RMT.
SW NAVAL" function is available.
F. Timer Operation
<Function>
To set the schedule operation "available" or "not available" by the signal from the control timer in case of connection
with the control timer (HYDE-E01H; Option).
The schedule operation can be set "available" or "not available" for each group, each zone or simultaneously
however, the operation schedule is all the same.
1. Depress the "ZONE" switch and the "GROUP" switch and select
the setting target.
(Refer to item 2 of "A. Setting Target Selection and Monitoring
Unit Operation Status" in page 18.)
The above
fi
gure shows the case of selecting
"ZONE 3, GROUP 6".
2. Depress the "TIMER" switch. Every time the "TIMER" switch
is depressed, the "TIMER" indication is turned ON and OFF
alternately. The group with timer setting is operated according
to setting schedule by the signal from the control timer.
The above
fi
gure shows the case of "ZONE 3,
GROUP 6" setting timer operation.
NOTE:
The above indications show the case of setting operation mode for "ZONE 3, GROUP 6"
Turned ON
The above
fi
gure shows the case of "ZONE 3,
GROUP 6" prohibited from operating by the
remote control switch.
Turned ON
The same setting procedure shall be performed for other
gro
ups.
142
Содержание HYE-W01
Страница 7: ......
Страница 9: ......
Страница 16: ...Model HYXE J01H Wired Remote Control Switch 7 ...
Страница 22: ...Model HYDE E01H 7 Day Timer 13 ...
Страница 24: ...Model HCCS H128H2C1YM HCCS H128H2C1NM Central Control 15 ...
Страница 25: ...Model HCCS H247R4C1E Central Control 16 ...
Страница 26: ...Model HYJ J01H Central Control 17 ...
Страница 27: ...Central Control Model HYJM S01H 18 ...
Страница 34: ...HYXE G01H 25 ...
Страница 35: ...HYXE G01H 26 ...
Страница 46: ...HYXE J01H 37 ...
Страница 47: ...HYXE J01H 38 ...
Страница 48: ...HYXE J01H 39 ...
Страница 49: ...HYXE J01H 40 ...
Страница 50: ...HYXE J01H 41 ...
Страница 51: ...HYXE J01H 42 ...
Страница 52: ...HYXE J01H 43 ...
Страница 53: ...HYXE J01H 44 ...
Страница 54: ...HYXE J01H 45 ...
Страница 55: ...HYXE J01H 46 ...
Страница 56: ...HYXE J01H 47 ...
Страница 57: ...HYXE J01H 48 ...
Страница 58: ...HYXE J01H 49 ...
Страница 59: ...HYXE J01H 50 ...
Страница 60: ...HYXE J01H 51 ...
Страница 61: ...HYXE J01H 52 ...
Страница 62: ...HYXE J01H 53 ...
Страница 63: ...HYXE J01H 54 ...
Страница 64: ...HYXE J01H 55 ...
Страница 65: ...HYXE J01H 56 ...
Страница 66: ...HYXE J01H 57 ...
Страница 67: ...HYXE J01H 58 ...
Страница 68: ...HYXE J01H 59 ...
Страница 69: ...HYXE J01H 60 ...
Страница 70: ...HYXE J01H 61 ...
Страница 71: ...HYXE J01H 62 ...
Страница 72: ...HYXE J01H 63 ...
Страница 73: ...HYXE J01H 64 ...
Страница 74: ...HYXE J01H 65 ...
Страница 75: ...HYXE J01H 66 ...
Страница 76: ...HYXE J01H 67 ...
Страница 115: ...HYDEͲE01H Hisense HYDE E01H 106 ...
Страница 116: ...HYDE E01H 107 ...
Страница 117: ...HYDE E01H 108 ...
Страница 119: ...HYXE A01H HYJE D02H HYXE A01H HYXE A01H HYXE A01H HYJE D02H HYJE D02H HYJE D02H HYDE E01H 110 ...
Страница 120: ...HYXE A01H HYJE D02H HYDE E01H 111 ...
Страница 121: ...HYDE E01H 112 ...
Страница 122: ...HYDE E01H 113 ...
Страница 123: ...HYDE E01H 114 ...
Страница 124: ...HYXE A01H HYJE D02H HYDE E01H 115 ...
Страница 125: ...HYXE A01H HYJE D02H HYDE E01H 116 ...
Страница 126: ...HYJE D02H HYDE E01H 117 ...
Страница 127: ...HYDE E01H 118 ...
Страница 128: ...HYJE D02H HYXE A01H HYDE E01H 119 ...
Страница 129: ...HYJE D02H HYJE D02H HYXE A01H Hisense Hisense HYDE E01H 120 ...
Страница 173: ...HYJ J01H 164 ...
Страница 174: ...HYJ J01H 165 ...
Страница 175: ...HYJ J01H 166 ...
Страница 176: ...HYJ J01H 167 ...
Страница 177: ...HYJ J01H 168 ...
Страница 178: ...HYJ J01H 169 ...
Страница 179: ... R QRW KDV WKLV IXQFWLRQ DV HW HYJ J01H 170 ...
Страница 180: ...HYJ J01H 171 ...
Страница 181: ...HYJ J01H 172 ...
Страница 182: ...HYJ J01H 173 ...