![Hirschmann OCTOPUS 16M-Train-BP Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/hirschmann/octopus-16m-train-bp/octopus-16m-train-bp_user-manual_2138108035.webp)
Installation OCTOPUS 8M/16M/24M/OS32
Release 16 06/2018
35
Power supply
OCTOPUS...PoE...,
OS32-...
Redundant power supply
Safety extra-low voltage (SELV/PELV) redundant inputs
disconnected.
Max. 5 A
Nominal voltage
48 V DC
Voltage range incl. maximum
tolerances
46 V DC ... 57 V DC
Connection type
M12 connector, 5 pin
Tightening torque
5.3 lb-in
(0.6 Nm)
Power loss buffer
> 10 ms
when using a PC150...
power supply unit
Back-up fuse
Nominal rating:
Characteristic:
5 A
slow blow
Peak inrush current
14 A
Insulation voltage
between supply voltage
connections and housing
OCTOPUS ...
(without PoE or Train)
800 V DC
Protective elements limit the
insulation voltage to 90 V DC
(1 mA)
OCTOPUS ... Train
OCTOPUS ... Train-BP
707 V DC
OCTOPUS...PoE..., OS32-...
2.250 V DC
“FAULT”
signal contact
Switching current
max. 1 A, resistive load
ab
Switching voltage
max. 60 V DC or max. 30 V AC,
SELV
Connection type
M12 connector, 5 pin
Tightening torque
5.3 lb-in
(0.6 Nm)
Climatic conditions during
operation
Ambient air temperature
c
−
40 °F ... +158 °F
(
−
40 °C ... +70 °C)
Humidity
10 % ... 100 %
(also in condensing
atmospheres)
d
Air pressure
minimum 795 hPa
(+6562 ft; +2000 m)
maximum 1060 hPa
(
−
1312 ft;
−
400 m)
Climatic conditions during
storage
Ambient air temperature
−
40 °F ... +185 °F
(
−
40 °C ... +85 °C)
Humidity
10 % ... 100 %
(also in condensing
atmospheres)
e
Air pressure
minimum 700 hPa
(+9842 ft; +3000 m)
maximum 1060 hPa
(
−
1312 ft;
−
400 m)
Protection classes
Laser protection
Class 1 in compliance with
IEC 60825-1
Degree of protection
IP65/67
f
Pollution degree
2