1.6
Display elements
After the supply voltage is set up, the software starts and initializes itself.
Afterwards, the device performs a self-test. During this process, various
LEDs light up. The process takes around 60 seconds.
Figure 1: Display elements
1 - Port status LEDs (here: for ports 1 to 4)
2 - Device status LEDs
1.6.1
Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
If the manual adjustment is active on the “FAULT” signal contact, then the
detected error display is independent of the setting of the signal contact.
LED
Display
Color
Activity
Meaning
P1
Supply voltage 1 Green
Lights up
Supply voltage is on
None
Supply voltage is too low
P2
Supply voltage 2 Green
Lights up
Supply voltage is on
None
Supply voltage is too low
FAULT Signal contact
Red
None
The signal contact is closed - it is
not
reporting any detected errors.
Lights up
The signal contact is open - it is reporting
a detected error.
RM
Ring Manager
—
None
The RM function is deactivated.
Green
Lights up
The RM function is active.
The redundant port is disabled.
flashing
The device detects an incorrect
configuration of the HIPER-Ring (e.g. the
ring is not connected to the ring port).
Yellow
Lights up
The RM function is active.
The redundant port is enabled.
OCTOPUS