![Hirschmann OCTOPUS 16M-Train-BP Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/hirschmann/octopus-16m-train-bp/octopus-16m-train-bp_user-manual_2138108021.webp)
Installation OCTOPUS 8M/16M/24M/OS32
Release 16 06/2018
21
Figure 2: Terminal cabel for connecting an external Management Station
The Terminal cable is available as an accessory.
See “Accessories” on page 42.
You will find a description of the V.24 interface in the “User Manual Basic
Configuration” document.
1.7.2
ACA interface (ACA21-M12)
This interface offers you the ability to connect the storage medium
AutoConfiguration Adapter ACA21-M12. This storage medium is used for
saving/loading the configuration and diagnostic functions, and for loading the
software.
This interface is a 5-pin, “A”-coded M12 socket with shielding.
Note:
The AutoConfiguration adapter
ACA11
-M12 available for certain
Hirschmann devices is incompatible with OCTOPUS 8M/16M/24M/OS32
devices.
Pin
Function
1
U
in
5 V
2
N.C. Not
used
3
D-
Data -
4
GND Ground (0 V)
5
D+
Data +
Table 2:
Pin assignment of the USB interface, 5 pin, “A”-coded M12 socket
5
M12
M12
DB9
DB9
2
3
5
1
2
3
4
1
2
3
4
6
7
8
9