4
Operating Precautions
Operating Precautions
Observe the following precautionary information to ensure that the device can be used safely and
in a manner that allows it to perform as described in its specifications.
Use of the device should confirm not only to its specifications, but also to the specifications of all
accessories, options and other equipment in use.
Installation Environment
WARNING
Installing the device in inappropriate locations could cause a malfunction of the
device, an accident. Avoid locations that are:
•
Exposed to direct sunlight or high temperatures
•
Exposed to corrosive or combustible gases
•
Exposed to strong electromagnetic fields or electrostatic charges
•
Near induction heating systems (such as high-frequency induction heating
systems and IH cooking equipment)
•
Susceptible to vibration
•
Exposed to water, oil, chemicals, or solvents
•
Exposed to high humidity or condensation
•
Exposed to high concentrations of dust particles
CAUTION
Do not place the device on an unstable or uneven surface. Doing so could cause the
device to fall or turn over, causing bodily injury or damage to the device.
Handling the Device
CAUTION
• The DUT could pop off the device and into the air while being connected. To prevent
injury, use gradual movements when handling clips and electrodes.
• To avoid damage to the device, avoid subjecting it to vibration or mechanical shock
during transportation and handling. Exercise particular care to avoid subjecting the
device to mechanical shock, for example by dropping.
• To prevent device damage or an electric shock, use only the screws that are originally
installed for securing clips or the short plate in place. If you have lost any screws or
find that any screws are damaged, please contact your authorized Hioki distributor or
reseller.
Measurements
CAUTION
• To avoid bodily injury or damage to the device, do not attempt to measure voltage
exceeding 42V.
• To avoid damage to the device, do not connect the charged capacitor to the device.
• Do not apply a voltage across the device’s measurement terminals while it is
connected to an impedance analyzer. It may cause damage to the impedance analyzer.
IMPORTANT
The accuracy of measured values obtained using the device is not guaranteed. Measured values
should be treated as reference values.
Shipping Precautions
During shipment of the device, handle it carefully so that it is not damaged due to a vibration or
shock.