87
Accuracy Table
Single‑phase
apparent power/
Balanced
3‑phase/4‑wire
apparent power
(
S
/
S
(3P4W)
)
Single‑phase
reactive power/
Balanced
3‑phase/4‑wire
reactive power
(
Q
/
Q
(3P4W)
)
Accuracy
±1 dgt relative to calculation from measured values
Range
configuration
For the above active power range configuration
,
the unit [W] is
replaced by [VA] for apparent power values. For reactive power
values
,
the unit [W] is replaced by [var].
Single‑phase
power factor/
Balanced
3‑phase/4‑wire
power factor
(
PF
/
PF
(3P4W)
)
Accuracy
±1 dgt relative to calculation from measured values
Range
configuration
Regeneration
−1.000 to −0.001
Consumption
0.000 to 1.000
Zero‑cross phase
angle (
φ
)*
Accuracy
±3°
Range
configuration
Lead
−180.0° to −0.1°
Lag
0.0° to 179.9°
*: Value is calculated based on the measurement of the zero-cross phase difference for the voltage and
current waveforms (positive [no sign] when the current lags the voltage and negative when the current
leads the voltage).