ALTERNATOR (J08E: REMY 12V-130A,135A,180A)
EN11–6
2.
INSTALL OR CONNECT
(1)
"I" and/or "R" terminal lead(s) (108 or 109), if used, to threaded termi-
nal stud(s) (136 and/or 146), washer(s) and hexagon nut(s) (131 and/
or 141).
NOTICE
Use suitable open end wrench to hold nut portion of terminal stud(s)
(125, 136 and/or 146).
Tightening Torque:
130A/135A : 2.0 N
m {20 kgf
cm, 17.7 lbf
in}
180A : 4.0 N
m {40 kgf
cm, 35.4 lbf
in}
(2)
Cap (138) to the "R" (or "Relay") pin terminal stud (146A) if necessary.
(3)
Ground lead (110) to "GRD" hole in SRE housing (1),with screw
assembly (159).
Tightening Torque:
6 N
m {61 kgf
cm, 55 lbf
in}
(4)
"BAT" output lead (111), washer (122) and nut (121) to "BAT" terminal
stud (125).
Tightening Torque:
130A/180A: 11 N
m {112 kgf
cm, 97.4 lbf
in}
135A: 9 N
m {92 kgf
cm, 79.7 lbf
in}
SHTS011061100008