EMISSION CONTROL (J08E)
EN10–12
DISMOUNTING AND MOUNTING
EN0110610H100001
1.
PREPARATION
! WARNING
Do not touch the exhaust pipe and muffler unit when it could be hot.
You can be severely burned.
NOTICE
•
If the quick joint used in DEF piping is once removed, DEF pow-
der will precipitate on the seal surface and leakage may occur
after reconnection. Before reconnecting, thoroughly check the
crystallize (=urea) for deposition of crystallized urea and foreign
matter. If deposition of crystallized urea is found, wash it with
hot water.
•
If you perform work with after-run not finished, an DEF filled in
the pipe will flow out when the quick connector is disconnected.
Be sure that after-run is finished.
•
What is after-run?
Remained DEF in the DEF injector, DEF pump and plumbing is
returned to DEF tank after engine off in order to prevent DEF fro-
zen in the plumbing and crystallization.
•
If you perform work immediately after the engine is stopped, hot
coolant may spout and you may get burned.
Before performing work, be sure that engine coolant is thor-
oughly cooled.
•
Formed tubes are used for DEF plumbing. Do not apply an
excessive force to tubes when working. If a tube is bent, must to
be replaced.
•
Do not directly touch an DEF or coolant flowing out from the
plumbing. If you have touched it, thoroughly rinse it out.
•
After removal, place a plastic cover to avoid entry of foreign mat-
ter into the pipe.
•
Place a cover immediately after removing the joint to avoid entry
of foreign matter into the DEF tank, DEF pump, and DEF injector.
•
When covering, use separate covers to avoid mixing of DEF and
coolant.
•
If removed by forcing, the quick connector may be damaged. If
removal is difficult to do, do not apply an excessive force but
remove dust attached around the joint.
•
The coolant pipe and DEF pipe are assembled for piping. Do not
disassemble them.
•
Do not use tools when disconnecting the quick connector.
•
Perform work with all the harness connectors fitted. If you per-
form work with connectors removed, rusting may result. Cover
the connectors to avoid splashing of coolant and DEF.
Содержание J08E-VC
Страница 130: ...EXHAUST SYSTEM J08E EN04 9 TAIL PIPE STACK TYPE 11 6 G 13 2 3 F 12 8 E 8 4 B 10 A 1 9 5 7 C C E D 13 G SAPH011060400009 ...
Страница 150: ...EXHAUST SYSTEM J08E EN04 29 SAPH011060400054 ...
Страница 176: ...LUBRICATING SYSTEM J08E EN05 2 LUBRICATING SYSTEM DIAGRAM EN0110605J100001 SHTS011060500001 ...
Страница 205: ...FUEL SYSTEM J08E EN07 4 SUPPLY PUMP DESCRIPTION EN0110607J100002 1 SAPH011060700003 1 Supply pump assembly ...