EMISSION CONTROL (J08E)
EN10–20
(2)
IMPORTANT POINT - MOUNTING
a.
Set the DEF pump at the mounting position.
b.
Connect the harness wire connector to the DEF pump.
c.
Mount the coolant and DEF hoses to the DEF pump.
d.
Mount the DEF pump to the specified position.
Tightening Torque:
15.2-22.8 N
m {155-232 kgf
cm, 11.2-16.8 lbf
ft}
(3)
REPLACE THE COOLANT CONNECTOR OF THE DEF PUMP.
a.
When the connector is exchanged, the O-ring must not be used
two times.
NOTICE
•
All sealing surface must be clean, contamination or particles are
not acceptable.
•
Mounting torque for connector: 5.0-6.0 N
m {51-61 kgf
cm, 3.7-4.4
lbf
ft}
•
Wrench size: 15 mm {0.59 in.}
•
For the mounting process, oil the O-ring with Mobile velocite oil
No.61
DEF
pump
Connector
Band
clamp
SHTS011061000034
SHTS011061000035
SHTS011061000036
77 mm {3.03 in.}
18 mm
{0.71 in.}
Coolant
connector
SHTS011061000037