EMISSION CONTROL (J08E)
EN10–11
INSPECTION
EN08Z0904H300001
DEF CONCENTRATION INSPECTION
NOTICE
There are three inspection methods for DEF; urea analyzer inspec-
tion, pH test paper inspection and refractive index measurement
inspection. Use one method from three for inspection.
1.
UREA ANALYZER INSPECTION
(1)
Extract DEF, put few drops on the urea analyzer to measure the urea
concentration and replace the DEF if the value is outside the standard
value.
Standard value: Concentration 31.8-33.2%
2.
PH TEST PAPER INSPECTION
(1)
Extract DEF, put few drops on the pH test paper to measure the color
change and replace the DEF if the value is outside the standard value.
HINT
When the digital type tester is used, standard value is 9.0 to 9.5.
3.
REFRACTIVE INDEX MEASUREMENT INSPECTION
(1)
Extract DEF, put few drops on the refractometer to measure the
refractive index and replace the DEF if the value is outside the stan-
dard value.
SAPH01Z081000001
SAPH01Z081000002
Concentration (%)
Standard value (number)
31.8-33.2
9
1
.
00
1
.
10
1
.
15
1
.2
0
1
.2
5
1
.
30
㧑
͠
1
.
00
1
.
10
1
.
15
1
.2
0
1
.2
5
1
.
30
1
.
35
1
.4
0
㧑
͠
SAPH01Z081000003
Concentration (%)
Standard value (%)
31.8-33.2
1.3814-1.3843
Содержание J08E-VC
Страница 130: ...EXHAUST SYSTEM J08E EN04 9 TAIL PIPE STACK TYPE 11 6 G 13 2 3 F 12 8 E 8 4 B 10 A 1 9 5 7 C C E D 13 G SAPH011060400009 ...
Страница 150: ...EXHAUST SYSTEM J08E EN04 29 SAPH011060400054 ...
Страница 176: ...LUBRICATING SYSTEM J08E EN05 2 LUBRICATING SYSTEM DIAGRAM EN0110605J100001 SHTS011060500001 ...
Страница 205: ...FUEL SYSTEM J08E EN07 4 SUPPLY PUMP DESCRIPTION EN0110607J100002 1 SAPH011060700003 1 Supply pump assembly ...