Step By Step Instructions for Typical Use Cases
54/89
NXHX 52-JTAG | Getting Started
DOC131004GS02EN | Revision 2 | English | 2013-11 | Released | Public
© Hilscher 2013
4. Configure NXHX board for DPM host interface mode.
Set the
S2
Host Mode switch on the NXHX board (see position
in
Device Drawing and Positions of the NXHX 52-JTAG
chapter on page
Parallel Dual-Port Memory 16 bit mode
.
If you are using an NXHX 52-JTAG board
hardware revision 2
, use
the following settings:
S2
SW
Setting
1 off
2 on
3 off
4 on
5 on
6 on
Table 6: Set Parallel Dual-Port Memory 16 Bit Mode at Switch S2 for Hardware Revision 2
If you are using an NXHX 52-JTAG board
hardware revision 3
, use
the following settings:
S2
SW
Setting
1 off
2 off
3 off
4 on
5 on
6 on
Table 7: Set Parallel Dual-Port Memory 16 Bit Mode at Switch S2 for Hardware Revision 3
Use the
S1
switch on the NXHX board (see position
in
Drawing and Positions of the NXHX 52-JTAG
chapter on page 12) to
set the boot strap options to
FLASH
boot mode
. Use the following
settings:
S1
SW
Setting
1 off
2 off
3 off
4 off
5 off
6 on
7 off
8 off
Table 8: Set Flash Boot Mode at Switch S1