
Edge Server
216/263
14.3.2
Selecting the protocols to scan for field devices
The protocols used to scan the individual field devices in the set IP-address
range are set in the Edge Server Control Center.
To activate or deactivate individual protocols:
Ø
Select menu entry
Scanning
in menu
Services
within the Edge Server
Control Center
Ê
The protocol configuration will be displayed:
Figure 140: Scan protocol configuration
Ø
On this page, you can set the scan protocols to be active or inactive
individually for each address of the configured IP-address range. For
the basic registration of the field devices, you should activate the scan
protocols SNMP and ARP.
Note:
Check the boxes IO-Link or PROFINET for IP-addresses in the
configured IP-address range only if the corresponding IO-Link
master devices or PROFINET devices are connected and
configured.
Ø
To save your settings in the Edge Server, click
.
ð
Thus, your scan protocol settings of the field devices are saved.
Edge Gateway | NIOT-E-TIB100-GB-RE (Remote)
DOC170501UM04EN | Revision 4 | English | 2018-08 | Released | Public
© Hilscher 2017 – 2018