Technical data
148/166
10 Technical data
Device
Category
Parameter
Value
General
Part number
1915.200
Functions
8-port IO-Link Master (Class A) Edge Device with sensorEDGE
Cloud connectivity
Power supply
Supply voltage
+24 V DC, –25%/+30% (18 V DC … 31.2 V DC)
Note
: Voltages above 34 V may cause permanent damage to
the device.
Voltages below approx. 10 V will cause a shutdown of the
device.
Note
: The sensorEDGE does not need or use auxiliary supply
voltage (U
2L
), even though the pins for the 2L auxiliary load
circuit are implemented on the device. The 1L and 2L load
circuits are galvanically isolated from each other.
Under-voltage warning
U
1L
< 18 V: 1L LED shows steady red
U
1L
> 17.7 V: 1L LED returns to steady green
Over-voltage warning
U
1L
> 30 V: 1L LED blinking red (4 Hz)
U
1L
< 29.7 V: 1L LED returns to steady green
Current consumption
(typical)
150 – 160 mA (at 24 V DC)
Maximum current at
supply connector
16 A with airflow of ~ 0.5 m/s.
3.36 A without airflow
Note
: Always protect the power supply with a circuit breaker or
fuse. For this purpose, use a 24 V DC / max. 16 A fuse or circuit
breaker with type B trip characteristics.
Reverse voltage
protection
Yes
Mains buffering
(power failure bridging)
10 ms (at 24 V)
Connector
M12 L-coded, male, 5-pin (4 + FE)
Recommended tightening torque of locking nut: 0.4 – 0.6 Nm
Mechanics and housing
Dimension (L x W x H)
200 mm x 60 mm x 30 mm
Weight
420 g
Housing material
Glass fiber reinforced plastic (PBT) according to UL 94-V0
Housing color
RAL 7035 (“light gray”)
Degree of protection
IP67 (EN 60529)
Protection class
III (EN 61140)
Mounting type
To be attached to carrier with two M4 screws.
Recommended tightening torque: 0.8 Nm
Admissible ambient
conditions
Ambient temperature for
operation
–25 °C … +60 °C at maximum current consumption per IO-Link
port of 400 mA without airflow.
–25 °C … +60 °C at maximum current consumption per IO-Link
port of 1800 mA with airflow of ~ 0.5 m/s.
Ambient temperature for
storage
–40 °C … +85 °C
Max. temperature change 3 K / min
Relative humidity
(operation)
5% … 95%
Pollution degree
3 (EN 60664-1)
Altitude
0 ... 2000 m
Overvoltage category
II (EN 60664-1)
netFIELD sensorEDGE | User manual
DOC200601UM01EN | Revision 1 | English | 2021-09 | Released | Public
© Hilscher 2021