Configuration
53/154
Range of
values
Time base
(Bits 7+6)
Multiplier
(Bits 5-0)
Resulting Cycle time
0
00
0
free-running mode
Note: If the free-running mode is chosen with a time base of 0, the W-
Master stack will automatically configure the Master cycle time to be the
Minimum Master cycle time based on the PD Segmentation length, Slot
Type, and Max Retry configurations.
1 … 64
00
1 … 63
65 … 127
01: 5ms
1 … 63 as
multiplier
5 ... 315 ms (Time Base * Multiplier)
Note: For W-Devices and W-Bridges the minimum possible transmission
time is 5 ms.
128 … 255
10 ...11:
reserved
1 … 63
reserved, do not use
Table 29: Calculation of the port cycle time of the IO-Link Wireless Master
Ø
Select the
Time base
and the
Time multiplier
for the “Port cycle time”
calculation.
Ê
The result is indicated as value or text in brackets,
e. g.
Port cycle time (Free running)
.
Settings > Validation level
Ø
Open the
Validation level
sub tab.
Settings tab, Validation level sub tab (example)
Parameter
Description
Value / Value range
Validation and
backup
The table below contains descriptions for the possible values for
the inspection level to be performed by the device and the Backup/
Restore behavior:
Default: No device check
Vendor ID*
Expected Vendor ID of connected device
This information is required to check the device for type
compatibility.
0 … 0xFFFF, Default: 0
Device ID*
Expected Device ID of connected device
This information is required to check the device for type
compatibility.
1 … 0xFFFFFF, Default:
0xFFFFF
Table 30: Settings in port configuration for IO-Link Device, Validation level sub tab
* Values are in hexadecimal
Ø
Under
Validation and backup
, configure possible values for the
inspection level to be performed by the device and the Backup/Restore
behavior.
NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning
DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public
© Hilscher 2020 - 2021