Configuration
48/154
If the execution was successful, the text
Write ok:
and the result is
displayed in the history. The entries in the history then have the following
structure:
Time - Index:Subindex - Write ok: <Result>
If the execution was not successful, an error message with error codes of
the IO-Link Wireless Master and IO-Link Device is displayed in the history.
The entries in the history then have the following structure:
Time - Index:Subindex - Write failed:
IOLMErrorCode(<error code of the IO-Link master>):
IOLDErrorCode(<error code of the IO-Link Device>)
Delete the history of read and write accesses
To clear the logged history of read and write accesses:
Ø
Click
Clear history
.
ð
The history of read and write accesses is deleted.
8.3.6.4
Master ISDU
The ISDU tab with the option Tigo Master Parameters enabled allows read
and write access to the IO-Link Wireless Master device, by means of
PortId
and
ArgBlockId
message format is used for this.
Figure 14: Display of the ISDU, read/write IO-Link Wireless Master parameters
Required rights
Changes to settings require operator or admin rights. If these are not
available, the ISDU tab is grayed out and the displayed values cannot be
edited.
NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning
DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public
© Hilscher 2020 - 2021