Note
• If Enable Arming is enabled, Forced Arming is only effective for Auto Arming.
• If there is a fault in the zone and the forbidden bypass when arming is opened, the arming
will fail.
System Faults
If the option is enabled, the device will upload the system fault report automatically.
One-Push Lock
If the option is enabled, the installer can lock other users.
Audible Tamper Alarm
If the option is enabled, the tamper alarm will link sounders and the control panel. If disabled,
the log will be uploaded when the tamper alarm is triggered, but the sound alarm will not be
triggered.
Authority Advanced Settings
Set advanced authority parameters.
Click Configuration → System → System Options → Advanced Settings to enter the Advanced
Settings page.
You can set the following parameters:
Enable Arming
When you enable the function, during the device arming procedure, the system will check the
configured fault checklist. When there is fault occurred during the arming procedure, the
procedure will be stopped.
Note
PKG keypad and the keyfob do not support this function. If this function is enabled, the arming
will fail if there is a fault. It is necessary to eliminate the fault or close the Enable Arming.
Fault Checklist
The system will check if the device has the faults in the checklist during the arming procedure.
Enable Arming with Fault
Check the faults in the Enable Arming with Fault list, and the device will not stop the arming
procedure when faults occurred.
Arming Indicator Keeps Light
If the device applies EN standard, by default, the function is disabled. In this case, if the device is
armed, the indicator will be solid blue for 5 s. And if the device is disarmed, the indicator will
flash 5 times.
Hybrid Security Control Panel User Manual