Fingerprint Time Attendance Terminal
48
Steps:
1.
In the editing interface, click the Door_1 button to edit the information of the
selected door.
1)
Door Magnetic
: The Door Magnetic is in the status of
Remain Closed
(excluding special conditions).
2)
Exit Button Type
: The Exit Button Type is in the status of
Remain Open
(excluding special conditions).
3)
Door Locked Time(s)
: After swiping the normal card and relay action, the
timer for locking the door starts working.
4)
Door Open for Disabled Person:
The door magnetic can be enabled with
appropriate delay after disabled person swipes the card.
5)
Door Open Timeout(s)
: The alarm can be triggered if the door has not been
close
6)
Enable Lock Door when Door Close
: This function has not been supported
yet.
7)
Duress Code
: The door can open by inputting the duress code when there is
a duress. At the same time, the access system can report the duress event.
8)
Super Password: The specific person can open the door by inputting the
super password.
2.
Click the Restore Default Value to restore all parameters into default settings.
3.
Click the Edit button to save parameters.
4.
Click the Hardware Parameters Downloading button to download the updated
parameters to the local memory of the device.
Note:
The attendance device does not support the function.