2)
If the HDD status is “Uninitialized,” check the corresponding HDD checkbox and click the
“Init” button.
Step 3
Verify the HDD is detected and is in good condition.
1)
Select “Menu > System Configuration > HDD > General.”
2)
If the HDD is not detected or the status is “Abnormal,” replace the dedicated HDD
according to the requirement.
Step 4
Check if the fault is solved by step 1 to step 3.
1)
If it is solved, finish the process.
2)
If not, contact an engineer from our company for further analysis.
•
Live view becomes stuck when video outputs locally.
Possible Reasons:
—
The frame rate has not reached the real-time frame rate.
Step 1
Check the parameters of Main Stream (Continuous) and Main Stream (Event).
Step 2
Select “Menu > Record > Parameters > Record,” and set the resolution of Main Stream
(Event) the same as the one of Main Stream (Continuous).
Step 3
Verify the frame rate is real-time frame rate.
Step 4
Select “Menu > Record > Parameters > Record,” and set the Frame Rate to Full Frame.
Step 5
Check if the fault is solved by the above steps.
Step 6
If it is solved, finish the process.
Step 7
If not, contact an engineer from our company for further analysis.
•
When using the device to get live view audio, there is no sound, there is too much noise, or the
volume is too low.
Possible Reasons:
—
Cable between the pickup and camera is not connected well; impedance mismatches or is
incompatible.
—
The stream type is not set to “Video & Audio.”
Step 1
Verify the cable between the pickup and camera is connected well, the impedance matches,
and is compatible.
Step 2
Verify the setting parameters are correct.
Step 3
Select “Menu > Record > Parameters > Record,” and set the Stream Type to “Audio & Video.”
Step 4
Check if the fault is solved by the above steps.