User Manual of 4-inch High Speed Dome
© Hikvision Digital Technology Co., Ltd. All Rights Reserved.
32
Note:
You can configure up to 7 alarms.
3.
Configure the alarm input.
Steps:
(1)
Move the cursor to
ALARM INPUT a
nd click the
IRIS+
to enter edit mode.
(2)
Click the up and down direction buttons to set the input status. You can configure it as
OPEN
(Normally open),
CLOSE
(Normally closed) or
OFF
(disable the alarm input).
(3)
Click
IRIS+
again to confirm.
Note:
If you set the status as
OPEN
, alarm will be triggered by high electricity level; if you set the
status as
CLOSE
, alarm will be triggered by low electricity level; if you set the status as
OFF
, it
will be triggered when this input channel is shut off.
4.
Configure the alarm linkage action.
You can specify the linked action when an alarm occurs. On the
ALARM ACT
submenu, you can
set the alarm action as preset from 1 to 8, pattern from 1 to 4, patrol from 1 to 8, panning scan,
tilting scan, random scan, frame scan, panoramic scan, day mode, night mode or none. You can
also set the alarm output for the alarm. Please refer to
Section 3.5.3
Configuring Auxiliary
Alarm Output
for details.
5.
Configure alarm priority.
Enter the
PRIORITY
menu and set the alarm priority as
HIGH
,
MID
or
LOW
.
If multiple alarms with different priorities are triggered at the same time, the dome only
responds to the alarm with the highest priority. If multiple alarms with the same priority are
triggered at the same time, then the dome will respond to each alarm according to the defined
alarm sequence.
3.5.2
Configuring Alarm Parameters
Purpose:
You can set the alarm related parameters following below instructions, including linkage action
interval, alarm duration and dome activity resumption.
Steps:
1.
Enter the alarm parameter configuration menu:
MAIN MENUS > DOME SETTINGS > ALARMS > ALARM SETTING
2.
Configure the interval of the alarm sequence.
When more than one alarm of the same priority occurs at the same time, the speed dome will
respond to one alarm first and then respond to the next one after the user-defined interval. You
can set the on
ALARM SEQUENCE
submenu
from 1 to 200 seconds.
3.
Configure the alarm rest delay.
If there’s a linkage action has already been triggered by an alarm input, the speed dome will
only respond to the input from the same channel again after the user-defined reset delay time
.
This is the rest time that the speed dome considers an alarm to be active when it’s physically
cleared. You can set the
ALARM REST DELAY
from 0 to 300 seconds.
4.
Resume the dome activity.
You can set
ALARM RESUME
to
ON
to enable the speed dome to resume its previous activity
after the triggered actions finished.
Notes: