ID5000 Series Smart Code Reader User Manual
55
Figure 8-38 Select Output Signal
8.4.2 Enable Line Inverter
The level inverter function allows the device to invert the electrical signal level of an I/O line, and
meets requirements of different devices for high or low electrical signal level.
You can go to
I/O Control Settings
→
Output
→
Line Out Inverter
to enable it.
Note
The
Line Out Inverter
function is disabled by default.
Figure 8-39 Enable Line Out Inverter
8.4.3 Set Event Source
The device supports outputting different trigger signals according to the event source you select.
Click
I/O Control Settings
→
Output
→
Line Out Activation Event
to select event source.
The device supports following event sources, including
Acquisition Start Active
,
Acquisition Stop
Active
,
Frame Burst Start Active
,
Frame Burst Stop Active
,
Exposure Start Active
,
Soft Trigger
Active
,
Hard Trigger Active
,
Counter Active
,
Timer Active
,
No Code Read
,
Read Success
, and
Light
Strobe Long
,
Compare Success
, and
Compare Fail
.
Note
●
Off
refers to no event source.
●
Some event sources support the function of trigger output cache, and you can go to
Feature
Tree
→
Trigger and IO Control
>
Line Out Cache
to enable it.
Содержание ID5000 Series
Страница 1: ...ID5000 Series Smart Code Reader User Manual ...
Страница 31: ...ID5000 Series Smart Code Reader User Manual 22 Figure 7 2 Code Reading ...
Страница 96: ...ID5000 Series Smart Code Reader User Manual 87 Figure 8 71 Event Report ...
Страница 103: ...ID5000 Series Smart Code Reader User Manual 94 Figure 10 2 Reboot Device ...
Страница 107: ...UD27157B ...