ID5000 Series Smart Code Reader User Manual
31
at a specific interval during code reading, and
Flash Long
means the light is solid during code
reading.
Lighting Duration
It sets the lighting duration and the unit is μs.
Lighting Delay Time
Note
This parameter is available only when you set
Flash Strobe
as the
Light Mode
.
It determines the delay time for lighting after exposure and the unit is μs.
Precharge Time
It det
ermines how earlier the light source starts lighting before exposure and the unit is μs.
Figure 8-9 Light Parameters
Note
The figure above is only for reference. The specific graphic user interface may differ by device
models.
Set External Lighting
If you select
External Lighting
as
Light Type
, you can set the following parameters.
Line Out Duration
The lighting duration of the external light source and the unit is μs.