CameraLink Line Scan Camera
·
User Manual
25
Figure 6-16
Set Trigger Mode
6.3.2 Set Hardware Trigger
The camera has 2 differential inputs (Line 0 and Line 3), and you can set hardware trigger as shown
below.
Steps:
1.
Click Acquisition Control > Trigger Selector.
2.
Select Line Start or Frame Burst Start as Trigger Selector, and On as Trigger Mode.
3.
Select Line 0 or Line 3 as Trigger Source.
Figure 6-17
Set Hardware Trigger
6.3.3 Set Shaft Encoder Control
The camera has shaft encoder control module, and it can receive the trigger from shaft encoder of
A and B channels. For example, the output signal of shaft encoder control module can be used as
the input signal of camera line trigger or frame trigger.
In line trigger mode, you can click Acquisition Control > Trigger Source, and select Encoder
Module Out as Trigger Source.
Содержание CameraLink