CameraLink Line Scan Camera
·
User Manual
45
The default output data format of color camera is RGB, and the default output data format of
mono camera is Mono 8. For different pixel formats, they have varied pixel size.
Table 9-1
Description
Pixel Format
Pixel Size(Bits/Pixel)
Mono 8
8
Mono 10
10
Mono 12
12
RGB 8
24
Click Image Format Control > Pixel Format, and set Pixel Format according to actual demands.
Figure 9-4
Set Pixel Format
Pixel format can be set only when you stop real-time acquisition.
For different models of cameras, the specific pixel format may differ, and the actual product
you purchased shall prevail.
9.5 Set Test Pattern
The camera supports test pattern function. When there is exception in real-time image, you can
check whether image of test mode have similar problem to determine the reason. This function is
disabled by default, and at this point, the outputted image by the camera is real-time image. If this
function is enabled, the outputted image by the camera is test image.
By default, the test pattern is Off.
For different models of cameras, the test pattern may differ, and the actual product you
purchased shall prevail.